Deployment Details
Survey: - IN2016_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 105
Gear: Autosal Salinometer,CTD 20 - SN 0552,CTD 23 - SN 1312,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 20 - SN 6022,Temperature CTD 21 - SN 6189,Transmissometer
When: 2016-06-14 19:49 to 2016-06-14 23:24 UTC
Where: 16° 30.2' S 170° 00.0' W
Maximum Depth (m): 5214.3
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
36 | 4.8 | 204.86 | 35.439 | < 0.02 | 27.12 | 0.17 | < 0.02 | 0.32 |
35 | 25.9 | 204.95 | 35.443 | < 0.02 | 27.06 | 0.17 | < 0.02 | 0.31 |
34 | 54.6 | 204.90 | 35.449 | < 0.02 | 27.05 | 0.17 | < 0.02 | 0.31 |
33 | 73.9 | 207.90 | 35.565 | < 0.02 | 26.43 | 0.15 | < 0.02 | 0.27 |
32 | 127.1 | 183.87 | 36.037 | 1.80 | 23.96 | 0.35 | 0.27 | 0.39 |
31 | 154.5 | 164.98 | 36.135 | 4.81 | 23.19 | 0.53 | 0.05 | 0.54 |
30 | 203.7 | 173.46 | 35.823 | 4.92 | 21.03 | 0.51 | 0.02 | 0.62 |
29 | 253.5 | 172.57 | 35.611 | 6.43 | 19.30 | 0.62 | < 0.02 | 1.15 |
28 | 302.4 | 159.84 | 35.277 | 10.49 | 16.89 | 0.93 | < 0.02 | 3.03 |
27 | 353 | 177.57 | 35.019 | 11.65 | 14.09 | 0.93 | < 0.02 | 3.63 |
26 | 403 | 168.06 | 34.761 | 17.03 | 12.19 | 1.29 | < 0.02 | 6.72 |
25 | 501.1 | 173.60 | 34.463 | 25.87 | 8.22 | 1.83 | < 0.02 | 14.39 |
24 | 601.9 | 177.62 | 34.401 | 29.95 | 6.35 | 2.06 | < 0.02 | 23.54 |
23 | 701.4 | 167.08 | 34.418 | 32.67 | 5.39 | 2.24 | < 0.02 | 37.18 |
22 | 802 | 162.12 | 34.437 | 33.98 | 4.76 | 2.34 | < 0.02 | 47.75 |
21 | 897.1 | 154.13 | 34.470 | 35.13 | 4.28 | 2.42 | < 0.02 | 60.00 |
20 | 1000.7 | 152.92 | 34.494 | 35.73 | 3.81 | 2.47 | < 0.02 | 69.93 |
19 | 1101.8 | 150.51 | 34.517 | 36.12 | 3.50 | 2.50 | < 0.02 | 77.79 |
18 | 1201.9 | 148.50 | 34.539 | 36.45 | 3.27 | 2.53 | < 0.02 | 85.25 |
17 | 1301.3 | 147.07 | 34.557 | 36.71 | 3.10 | 2.55 | < 0.02 | 91.08 |
16 | 1401.7 | 149.03 | 34.568 | 36.59 | 2.88 | 2.54 | < 0.02 | 95.45 |
15 | 1601.5 | 149.08 | 34.593 | 36.63 | 2.62 | 2.54 | < 0.02 | 103.74 |
14 | 1800.5 | 149.84 | 34.612 | 36.67 | 2.43 | 2.54 | < 0.02 | 110.51 |
13 | 2000.5 | 151.13 | 34.629 | 36.64 | 2.21 | 2.54 | < 0.02 | 116.52 |
12 | 2250.4 | 153.14 | 34.646 | 36.56 | 2.02 | 2.53 | < 0.02 | 122.31 |
11 | 2500.9 | 156.18 | 34.657 | 36.42 | 1.88 | 2.52 | < 0.02 | 126.13 |
10 | 2750.8 | 158.81 | 34.667 | 36.27 | 1.77 | 2.51 | < 0.02 | 129.11 |
9 | 3000.2 | 161.67 | 34.674 | 36.09 | 1.68 | 2.50 | < 0.02 | 130.99 |
8 | 3301.5 | 166.45 | 34.681 | 35.79 | 1.59 | 2.47 | < 0.02 | 131.75 |
7 | 3601 | 173.20 | 34.687 | 35.28 | 1.51 | 2.44 | < 0.02 | 130.59 |
6 | 3900.6 | 190.21 | 34.704 | 33.86 | 1.40 | 2.33 | < 0.02 | 121.77 |
5 | 4200.3 | 205.17 | 34.713 | 32.81 | 1.22 | 2.25 | < 0.02 | 117.50 |
4 | 4500.7 | 209.86 | 34.710 | 32.78 | 1.08 | 2.24 | < 0.02 | 120.42 |
3 | 4900.9 | 210.93 | 34.709 | 32.78 | 1.08 | 2.24 | < 0.02 | 121.23 |
2 | 5070.4 | 211.47 | 34.709 | 32.80 | 1.09 | 2.25 | < 0.02 | 121.58 |
1 | 5214.3 | 211.25 | 34.708 | 32.81 | 1.11 | 2.25 | < 0.02 | 121.59 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
Temperature CTD 20 - SN 6022 | Sea-Bird Electronics Inc | SBE3T | 6022 | Temperature (deg C) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |