Deployment Details
Survey: - IN2016_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 103
Gear: Autosal Salinometer,CTD 20 - SN 0552,CTD 23 - SN 1312,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 20 - SN 6022,Temperature CTD 21 - SN 6189,Transmissometer
When: 2016-06-14 06:52 to 2016-06-14 10:30 UTC
Where: 17° 29.9' S 170° 00.1' W
Maximum Depth (m): 5101.6
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
36 | 5.2 | 205.80 | 35.433 | < 0.02 | 26.72 | 0.17 | < 0.02 | 0.47 |
35 | 35.5 | 205.89 | 35.438 | < 0.02 | 26.71 | 0.16 | < 0.02 | 0.46 |
34 | 62 | 206.16 | 35.483 | < 0.02 | 26.48 | 0.17 | < 0.02 | 0.46 |
33 | 86.8 | 204.99 | 35.712 | < 0.02 | 26.42 | 0.18 | < 0.02 | 0.48 |
32 | 111.6 | 200.57 | 35.849 | 0.04 | 24.42 | 0.19 | 0.02 | 0.45 |
31 | 166.1 | 191.51 | 35.801 | 1.69 | 22.04 | 0.26 | 0.08 | 0.44 |
30 | 215.8 | 187.40 | 35.699 | 3.35 | 20.39 | 0.34 | < 0.02 | 0.60 |
29 | 266.4 | 188.02 | 35.510 | 4.76 | 18.60 | 0.44 | < 0.02 | 0.99 |
28 | 316.4 | 190.70 | 35.326 | 6.36 | 16.79 | 0.54 | < 0.02 | 1.53 |
27 | 365.8 | 186.37 | 35.094 | 9.74 | 15.03 | 0.78 | < 0.02 | 2.80 |
26 | 436.3 | 155.20 | 34.640 | 20.95 | 10.93 | 1.57 | < 0.02 | 10.51 |
25 | 535.9 | 146.44 | 34.493 | 28.47 | 7.86 | 2.03 | < 0.02 | 21.25 |
24 | 635.4 | 179.76 | 34.397 | 29.78 | 6.15 | 2.06 | < 0.02 | 24.33 |
23 | 735.2 | 174.67 | 34.395 | 32.21 | 5.15 | 2.22 | < 0.02 | 36.04 |
22 | 835.1 | 162.52 | 34.436 | 33.92 | 4.60 | 2.35 | < 0.02 | 49.68 |
21 | 935.5 | 158.01 | 34.466 | 34.95 | 4.03 | 2.42 | < 0.02 | 61.80 |
20 | 1085.1 | 150.15 | 34.517 | 35.86 | 3.52 | 2.50 | < 0.02 | 77.94 |
19 | 1135.5 | 149.88 | 34.525 | 36.00 | 3.39 | 2.51 | < 0.02 | 81.08 |
18 | 1235.6 | 149.08 | 34.544 | 36.17 | 3.15 | 2.52 | < 0.02 | 87.41 |
17 | 1335.8 | 149.97 | 34.560 | 36.30 | 2.94 | 2.52 | < 0.02 | 92.78 |
16 | 1466 | 148.81 | 34.582 | 36.48 | 2.73 | 2.54 | < 0.02 | 100.15 |
15 | 1666.5 | 149.35 | 34.601 | 36.48 | 2.53 | 2.54 | < 0.02 | 106.92 |
14 | 1865.9 | 149.88 | 34.617 | 36.54 | 2.34 | 2.54 | < 0.02 | 112.85 |
13 | 2086.1 | 151.31 | 34.634 | 36.52 | 2.16 | 2.54 | < 0.02 | 118.67 |
12 | 2336.5 | 153.37 | 34.647 | 36.46 | 2.00 | 2.53 | < 0.02 | 123.25 |
11 | 2586 | 155.64 | 34.659 | 36.31 | 1.86 | 2.52 | < 0.02 | 127.36 |
10 | 2835.9 | 157.47 | 34.667 | 36.19 | 1.77 | 2.51 | < 0.02 | 130.38 |
9 | 3100 | 160.11 | 34.674 | 36.01 | 1.69 | 2.50 | < 0.02 | 131.86 |
8 | 3400.4 | 162.66 | 34.681 | 35.95 | 1.60 | 2.49 | < 0.02 | 134.51 |
7 | 3698.8 | 181.95 | 34.699 | 34.29 | 1.47 | 2.36 | < 0.02 | 124.84 |
6 | 3999.3 | 203.25 | 34.714 | 32.70 | 1.28 | 2.25 | < 0.02 | 116.47 |
5 | 4299.2 | 164.31 | 34.671 | 35.75 | 1.11 | 2.47 | < 0.02 | 127.52 |
4 | 4599.2 | 211.29 | 34.709 | 32.65 | 1.05 | 2.24 | < 0.02 | 121.61 |
3 | 4901.7 | 211.56 | 34.708 | 32.67 | 1.06 | 2.24 | < 0.02 | 122.21 |
2 | 5001.5 | 211.65 | 34.708 | 32.68 | 1.07 | 2.24 | < 0.02 | 122.33 |
1 | 5101.6 | 212.54 | 34.707 | 32.65 | 1.08 | 2.24 | < 0.02 | 122.30 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
Temperature CTD 20 - SN 6022 | Sea-Bird Electronics Inc | SBE3T | 6022 | Temperature (deg C) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |