Deployment Details
Survey: - IN2016_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 102
Gear: Autosal Salinometer,CTD 20 - SN 0552,CTD 23 - SN 1312,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 20 - SN 6022,Temperature CTD 21 - SN 6189,Transmissometer
When: 2016-06-13 21:39 to 2016-06-14 01:15 UTC
Where: 17° 59.9' S 170° 00.0' W
Maximum Depth (m): 4991.5
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
36 | 5 | 206.65 | 35.468 | < 0.02 | 26.51 | 0.15 | < 0.02 | 0.38 |
35 | 23.1 | 206.60 | 35.468 | 0.02 | 26.49 | 0.15 | < 0.02 | 0.37 |
34 | 50.9 | 206.60 | 35.466 | 0.02 | 26.48 | 0.15 | < 0.02 | 0.38 |
33 | 75.3 | 209.28 | 35.669 | 0.02 | 26.00 | 0.13 | < 0.02 | 0.32 |
32 | 100.1 | 209.46 | 35.727 | 0.02 | 25.63 | 0.14 | < 0.02 | 0.34 |
31 | 134.6 | 202.40 | 35.788 | 0.12 | 23.67 | 0.15 | 0.03 | 0.32 |
30 | 200.2 | 185.34 | 35.776 | 3.30 | 21.21 | 0.31 | < 0.02 | 0.44 |
29 | 249.8 | 191.46 | 35.640 | 3.87 | 19.64 | 0.32 | < 0.02 | 0.56 |
28 | 300.4 | 190.75 | 35.482 | 5.34 | 18.33 | 0.43 | < 0.02 | 0.97 |
27 | 350.4 | 190.48 | 35.216 | 8.64 | 15.91 | 0.64 | < 0.02 | 1.87 |
26 | 406.1 | 191.46 | 34.854 | 14.97 | 12.66 | 1.03 | < 0.02 | 3.93 |
25 | 505.9 | 219.82 | 34.535 | 20.64 | 9.12 | 1.34 | < 0.02 | 5.40 |
24 | 604.6 | 224.91 | 34.364 | 26.05 | 6.79 | 1.69 | < 0.02 | 10.15 |
23 | 703.6 | 193.02 | 34.359 | 30.99 | 5.90 | 2.04 | < 0.02 | 22.01 |
22 | 803.6 | 172.70 | 34.391 | 34.05 | 4.99 | 2.26 | < 0.02 | 37.29 |
21 | 902.9 | 168.01 | 34.417 | 35.07 | 4.45 | 2.34 | < 0.02 | 47.90 |
20 | 1002.1 | 163.41 | 34.455 | 35.96 | 3.80 | 2.42 | < 0.02 | 60.96 |
19 | 1101.9 | 159.31 | 34.498 | 36.40 | 3.37 | 2.46 | < 0.02 | 73.48 |
18 | 1201.5 | 158.95 | 34.524 | 36.60 | 3.09 | 2.48 | < 0.02 | 81.49 |
17 | 1301.4 | 155.60 | 34.571 | 36.81 | 2.88 | 2.50 | < 0.02 | 89.52 |
16 | 1401.3 | 153.10 | 34.606 | 36.97 | 2.75 | 2.52 | < 0.02 | 95.84 |
15 | 1600.5 | 150.24 | 34.621 | 37.14 | 2.47 | 2.54 | < 0.02 | 107.73 |
14 | 1800.8 | 149.53 | 34.621 | 37.26 | 2.31 | 2.55 | < 0.02 | 113.63 |
13 | 2001.6 | 149.61 | 34.631 | 37.29 | 2.20 | 2.55 | < 0.02 | 117.74 |
12 | 2251.1 | 150.28 | 34.645 | 37.28 | 2.04 | 2.55 | < 0.02 | 123.32 |
11 | 2500.6 | 152.92 | 34.656 | 37.10 | 1.92 | 2.54 | < 0.02 | 126.52 |
10 | 2750.5 | 153.86 | 34.664 | 37.02 | 1.82 | 2.54 | < 0.02 | 130.17 |
9 | 3000.9 | 156.63 | 34.671 | 36.86 | 1.73 | 2.53 | < 0.02 | 132.18 |
8 | 3300.4 | 161.58 | 34.678 | 36.53 | 1.65 | 2.50 | < 0.02 | 132.96 |
7 | 3601.3 | 175.52 | 34.692 | 35.41 | 1.51 | 2.41 | < 0.02 | 127.62 |
6 | 3901.1 | 195.12 | 34.708 | 33.90 | 1.35 | 2.30 | < 0.02 | 118.81 |
5 | 4200.2 | 206.78 | 34.711 | 33.31 | 1.15 | 2.25 | < 0.02 | 118.39 |
4 | 4500.3 | 211.07 | 34.709 | 33.22 | 1.05 | 2.25 | < 0.02 | 120.57 |
3 | 4800.1 | 211.38 | 34.709 | 33.23 | 1.05 | 2.25 | < 0.02 | 121.24 |
2 | 4900.6 | 211.56 | 34.708 | 33.18 | 1.06 | 2.25 | < 0.02 | 121.46 |
1 | 4991.5 | 211.74 | 34.709 | 33.18 | 1.07 | 2.25 | < 0.02 | 121.49 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
Temperature CTD 20 - SN 6022 | Sea-Bird Electronics Inc | SBE3T | 6022 | Temperature (deg C) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |