Deployment Details
Survey: - IN2016_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 101
Gear: Autosal Salinometer,CTD 20 - SN 0552,CTD 23 - SN 1312,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 20 - SN 6022,Temperature CTD 21 - SN 6189,Transmissometer
When: 2016-06-13 15:03 to 2016-06-13 18:54 UTC
Where: 18° 30.0' S 170° 00.1' W
Maximum Depth (m): 5345.5
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
36 | 4.3 | 207.41 | 35.482 | < 0.02 | 26.20 | 0.15 | < 0.02 | 0.28 |
35 | 19.7 | 207.45 | 35.491 | < 0.02 | 26.20 | 0.15 | < 0.02 | 0.30 |
34 | 39.1 | 209.42 | 35.661 | < 0.02 | 25.57 | 0.14 | < 0.02 | 0.27 |
33 | 64.7 | 209.50 | 35.725 | < 0.02 | 25.37 | 0.13 | < 0.02 | 0.26 |
32 | 88.8 | 209.55 | 35.730 | < 0.02 | 25.35 | 0.14 | < 0.02 | 0.26 |
31 | 133.7 | 202.05 | 35.774 | 0.48 | 22.62 | 0.16 | 0.09 | 0.21 |
30 | 184.5 | 189.50 | 35.745 | 2.74 | 21.30 | 0.28 | < 0.02 | 0.31 |
29 | 235 | 191.42 | 35.644 | 3.43 | 19.77 | 0.32 | < 0.02 | 0.45 |
28 | 283.8 | 198.21 | 35.506 | 4.36 | 18.08 | 0.38 | < 0.02 | 0.71 |
27 | 333.9 | 187.71 | 35.198 | 8.25 | 15.73 | 0.67 | < 0.02 | 1.94 |
26 | 388 | 190.39 | 35.050 | 10.72 | 14.05 | 0.82 | < 0.02 | 2.74 |
25 | 466 | 198.43 | 34.701 | 16.69 | 10.83 | 1.18 | < 0.02 | 4.52 |
24 | 565.8 | 235.99 | 34.414 | 21.92 | 7.53 | 1.49 | < 0.02 | 6.36 |
23 | 665.5 | 199.72 | 34.359 | 28.37 | 6.30 | 1.94 | < 0.02 | 17.52 |
22 | 763.6 | 187.98 | 34.360 | 31.08 | 5.45 | 2.12 | < 0.02 | 26.98 |
21 | 865.7 | 177.04 | 34.384 | 33.36 | 4.60 | 2.28 | < 0.02 | 40.32 |
20 | 965.8 | 163.28 | 34.443 | 34.74 | 4.12 | 2.39 | < 0.02 | 55.98 |
19 | 1065.7 | 161.54 | 34.472 | 35.35 | 3.65 | 2.44 | < 0.02 | 65.75 |
18 | 1165.5 | 159.17 | 34.508 | 35.73 | 3.25 | 2.48 | < 0.02 | 76.70 |
17 | 1264.6 | 158.19 | 34.533 | 35.92 | 3.00 | 2.49 | < 0.02 | 84.06 |
16 | 1364.9 | 153.86 | 34.570 | 36.21 | 2.73 | 2.51 | < 0.02 | 95.26 |
15 | 1534.7 | 150.55 | 34.597 | 36.47 | 2.54 | 2.53 | < 0.02 | 104.69 |
14 | 1734.8 | 149.44 | 34.614 | 36.59 | 2.38 | 2.54 | < 0.02 | 111.23 |
13 | 1935.9 | 149.44 | 34.630 | 36.67 | 2.21 | 2.55 | < 0.02 | 117.09 |
12 | 2164.8 | 150.42 | 34.640 | 36.67 | 2.07 | 2.55 | < 0.02 | 122.12 |
11 | 2415.7 | 150.73 | 34.654 | 36.72 | 1.93 | 2.55 | < 0.02 | 127.31 |
10 | 2665.3 | 152.87 | 34.663 | 36.62 | 1.83 | 2.54 | < 0.02 | 130.50 |
9 | 2915.3 | 155.15 | 34.670 | 36.43 | 1.75 | 2.53 | < 0.02 | 132.64 |
8 | 3200.4 | 159.44 | 34.676 | 36.21 | 1.67 | 2.52 | < 0.02 | 133.54 |
7 | 3564.4 | 170.69 | 34.687 | 35.30 | 1.54 | 2.44 | < 0.02 | 130.19 |
6 | 3964.9 | 196.82 | 34.709 | 33.26 | 1.34 | 2.28 | < 0.02 | 118.22 |
5 | 4364.4 | 208.70 | 34.712 | 32.70 | 1.12 | 2.24 | < 0.02 | 118.74 |
4 | 4765.7 | 211.56 | 34.708 | 32.69 | 1.06 | 2.24 | < 0.02 | 120.88 |
3 | 5165.5 | 211.74 | 34.709 | 32.68 | 1.09 | 2.24 | < 0.02 | 121.42 |
2 | 5262.5 | 211.74 | 34.709 | 32.69 | 1.10 | 2.24 | < 0.02 | 121.50 |
1 | 5345.5 | 211.78 | 34.708 | 32.71 | 1.11 | 2.24 | < 0.02 | 121.46 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
Temperature CTD 20 - SN 6022 | Sea-Bird Electronics Inc | SBE3T | 6022 | Temperature (deg C) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |