Deployment Details
Survey: - IN2016_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 99
Gear: Autosal Salinometer,CTD 20 - SN 0552,CTD 23 - SN 1312,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 20 - SN 6022,Temperature CTD 21 - SN 6189,Transmissometer
When: 2016-06-13 03:03 to 2016-06-13 06:49 UTC
Where: 19° 29.7' S 170° 00.2' W
Maximum Depth (m): 4984.6
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
36 | 4.9 | 211.02 | 35.687 | < 0.02 | 25.24 | 0.12 | < 0.02 | 0.29 |
35 | 26.5 | 211.16 | 35.685 | < 0.02 | 25.24 | 0.12 | < 0.02 | 0.29 |
34 | 50.4 | 210.84 | 35.693 | < 0.02 | 25.23 | 0.12 | < 0.02 | 0.28 |
33 | 75.9 | 210.98 | 35.705 | < 0.02 | 25.13 | 0.11 | < 0.02 | 0.27 |
32 | 106.4 | 205.40 | 35.763 | < 0.02 | 23.49 | 0.13 | < 0.02 | 0.26 |
31 | 152 | 194.41 | 35.778 | 1.45 | 21.76 | 0.22 | 0.11 | 0.28 |
30 | 200.5 | 189.23 | 35.713 | 3.01 | 20.50 | 0.30 | < 0.02 | 0.43 |
29 | 249.9 | 187.93 | 35.563 | 4.40 | 18.88 | 0.39 | < 0.02 | 0.75 |
28 | 301.6 | 193.87 | 35.378 | 5.67 | 17.03 | 0.47 | < 0.02 | 1.16 |
27 | 351.1 | 199.01 | 35.289 | 7.09 | 15.79 | 0.56 | < 0.02 | 1.61 |
26 | 401.4 | 180.74 | 34.824 | 14.61 | 12.46 | 1.11 | < 0.02 | 4.86 |
25 | 501.4 | 210.71 | 34.580 | 18.71 | 9.43 | 1.31 | < 0.02 | 5.36 |
24 | 600.1 | 231.79 | 34.369 | 23.65 | 7.02 | 1.61 | < 0.02 | 8.40 |
23 | 701.3 | 220.18 | 34.327 | 27.24 | 5.96 | 1.85 | < 0.02 | 14.65 |
22 | 801.5 | 194.14 | 34.347 | 30.76 | 5.32 | 2.10 | < 0.02 | 26.07 |
21 | 901.9 | 178.47 | 34.379 | 33.06 | 4.66 | 2.26 | < 0.02 | 38.79 |
20 | 1001.8 | 167.61 | 34.427 | 34.62 | 4.02 | 2.38 | < 0.02 | 54.15 |
19 | 1101.1 | 160.60 | 34.472 | 35.33 | 3.61 | 2.44 | < 0.02 | 66.45 |
18 | 1200.7 | 159.13 | 34.511 | 35.71 | 3.17 | 2.47 | < 0.02 | 78.21 |
17 | 1300.7 | 157.70 | 34.544 | 35.93 | 2.90 | 2.49 | < 0.02 | 87.33 |
16 | 1401.2 | 153.90 | 34.576 | 36.22 | 2.67 | 2.52 | < 0.02 | 97.37 |
15 | 1601.3 | 149.84 | 34.606 | 36.51 | 2.47 | 2.54 | < 0.02 | 108.01 |
14 | 1800.8 | 149.12 | 34.621 | 36.67 | 2.32 | 2.55 | < 0.02 | 113.90 |
13 | 2000.3 | 149.39 | 34.632 | 36.73 | 2.19 | 2.55 | < 0.02 | 118.20 |
12 | 2250.6 | 149.79 | 34.645 | 36.75 | 2.03 | 2.56 | < 0.02 | 124.14 |
11 | 2500.7 | 150.24 | 34.657 | 36.77 | 1.91 | 2.56 | < 0.02 | 129.51 |
10 | 2751 | 153.46 | 34.664 | 36.62 | 1.80 | 2.54 | < 0.02 | 131.85 |
9 | 3000 | 154.44 | 34.670 | 36.53 | 1.74 | 2.54 | < 0.02 | 133.96 |
8 | 3300.4 | 158.86 | 34.677 | 36.26 | 1.67 | 2.52 | < 0.02 | 134.35 |
7 | 3598.6 | 170.47 | 34.687 | 35.33 | 1.55 | 2.45 | < 0.02 | 130.63 |
6 | 3899.8 | 192.09 | 34.708 | 33.49 | 1.44 | 2.31 | < 0.02 | 118.69 |
5 | 4199.8 | 205.17 | 34.712 | 32.80 | 1.21 | 2.26 | < 0.02 | 118.13 |
4 | 4498.9 | 211.02 | 34.710 | 32.74 | 1.04 | 2.25 | < 0.02 | 120.91 |
3 | 4801.1 | 211.56 | 34.708 | 32.80 | 1.03 | 2.26 | < 0.02 | 122.24 |
2 | 4902.6 | 211.51 | 34.708 | 32.80 | 1.04 | 2.25 | < 0.02 | 122.35 |
1 | 4984.6 | 211.65 | 34.708 | 32.78 | 1.05 | 2.25 | < 0.02 | 122.35 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
Temperature CTD 20 - SN 6022 | Sea-Bird Electronics Inc | SBE3T | 6022 | Temperature (deg C) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |