Deployment Details
Survey: - IN2016_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 97
Gear: Autosal Salinometer,CTD 20 - SN 0552,CTD 23 - SN 1312,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 20 - SN 6022,Temperature CTD 21 - SN 6189,Transmissometer
When: 2016-06-12 12:47 to 2016-06-12 17:32 UTC
Where: 20° 30.2' S 169° 59.9' W
Maximum Depth (m): 5765.7
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
36 | 4.3 | 209.46 | 35.567 | < 0.02 | 25.52 | 0.13 | < 0.02 | 0.38 |
35 | 35.8 | 209.46 | 35.568 | < 0.02 | 25.52 | 0.13 | < 0.02 | 0.37 |
34 | 60.7 | 210.93 | 35.653 | < 0.02 | 24.90 | 0.10 | < 0.02 | 0.28 |
33 | 86.1 | 211.92 | 35.635 | < 0.02 | 24.73 | 0.09 | < 0.02 | 0.26 |
32 | 135 | 197.27 | 35.755 | 1.20 | 22.19 | 0.20 | 0.06 | 0.36 |
31 | 177.3 | 195.30 | 35.747 | 2.01 | 21.11 | 0.23 | 0.03 | 0.37 |
30 | 216.3 | 195.93 | 35.688 | 2.66 | 20.08 | 0.27 | < 0.02 | 0.40 |
29 | 267.1 | 204.73 | 35.628 | 2.53 | 18.85 | 0.26 | < 0.02 | 0.50 |
28 | 316.7 | 204.10 | 35.512 | 3.83 | 17.64 | 0.34 | < 0.02 | 0.70 |
27 | 365.7 | 190.88 | 35.188 | 8.12 | 15.63 | 0.66 | < 0.02 | 1.89 |
26 | 435.8 | 191.15 | 34.885 | 13.03 | 12.81 | 0.99 | < 0.02 | 3.62 |
25 | 535.3 | 190.52 | 34.503 | 21.95 | 8.97 | 1.58 | < 0.02 | 9.15 |
24 | 635.4 | 210.98 | 34.363 | 25.94 | 6.71 | 1.81 | < 0.02 | 12.66 |
23 | 750.9 | 201.73 | 34.342 | 29.26 | 5.68 | 2.02 | < 0.02 | 21.14 |
22 | 837.3 | 180.03 | 34.375 | 31.94 | 5.11 | 2.22 | < 0.02 | 33.10 |
21 | 934.4 | 169.80 | 34.406 | 33.56 | 4.60 | 2.34 | < 0.02 | 44.60 |
20 | 1036 | 164.22 | 34.444 | 34.68 | 3.95 | 2.42 | < 0.02 | 57.93 |
19 | 1135 | 162.52 | 34.480 | 35.20 | 3.44 | 2.46 | < 0.02 | 69.56 |
18 | 1235.6 | 161.23 | 34.516 | 35.50 | 3.04 | 2.48 | < 0.02 | 79.57 |
17 | 1335.3 | 159.31 | 34.541 | 35.68 | 2.87 | 2.50 | < 0.02 | 86.66 |
16 | 1465.5 | 154.57 | 34.579 | 36.08 | 2.66 | 2.53 | < 0.02 | 98.40 |
15 | 1665.3 | 149.97 | 34.605 | 36.30 | 2.48 | 2.55 | < 0.02 | 107.73 |
14 | 1865.8 | 149.61 | 34.618 | 36.42 | 2.35 | 2.55 | < 0.02 | 112.73 |
13 | 2086 | 149.97 | 34.633 | 36.55 | 2.18 | 2.56 | < 0.02 | 118.80 |
12 | 2336.3 | 150.51 | 34.647 | 36.55 | 2.03 | 2.56 | < 0.02 | 124.17 |
11 | 2584.9 | 151.04 | 34.658 | 36.59 | 1.90 | 2.57 | < 0.02 | 129.51 |
10 | 2800.3 | 150.86 | 34.664 | 36.63 | 1.82 | 2.57 | < 0.02 | 132.92 |
9 | 3100.4 | 154.39 | 34.673 | 36.41 | 1.71 | 2.55 | < 0.02 | 135.02 |
8 | 3400.7 | 166.59 | 34.685 | 35.44 | 1.57 | 2.48 | < 0.02 | 131.79 |
7 | 3735.6 | 194.36 | 34.711 | 33.10 | 1.42 | 2.30 | < 0.02 | 116.42 |
6 | 4135.3 | 207.58 | 34.715 | 32.39 | 1.20 | 2.24 | < 0.02 | 116.09 |
5 | 4536 | 210.49 | 34.711 | 32.51 | 1.10 | 2.25 | < 0.02 | 119.57 |
4 | 4936.1 | 211.60 | 34.708 | 32.59 | 1.07 | 2.26 | < 0.02 | 121.66 |
3 | 5336.9 | 211.74 | 34.707 | 32.65 | 1.09 | 2.26 | < 0.02 | 122.35 |
2 | 5572.7 | 211.83 | 34.707 | 32.64 | 1.12 | 2.26 | < 0.02 | 122.44 |
1 | 5765.7 | 211.60 | 34.708 | 32.63 | 1.15 | 2.26 | < 0.02 | 122.39 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
Temperature CTD 20 - SN 6022 | Sea-Bird Electronics Inc | SBE3T | 6022 | Temperature (deg C) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |