Deployment Details
Survey: - IN2016_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 96
Gear: Autosal Salinometer,CTD 20 - SN 0552,CTD 23 - SN 1312,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 20 - SN 6022,Temperature CTD 21 - SN 6189,Transmissometer
When: 2016-06-12 05:52 to 2016-06-12 10:06 UTC
Where: 20° 59.8' S 169° 59.9' W
Maximum Depth (m): 5576.9
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
36 | 5.5 | 211.65 | 35.620 | < 0.02 | 24.97 | 0.11 | < 0.02 | 0.29 |
35 | 25.9 | 211.56 | 35.635 | < 0.02 | 24.93 | 0.11 | < 0.02 | 0.26 |
34 | 51.4 | 212.45 | 35.649 | < 0.02 | 24.65 | 0.09 | < 0.02 | 0.24 |
33 | 76.5 | 212.50 | 35.640 | < 0.02 | 24.61 | 0.09 | < 0.02 | 0.22 |
32 | 111.4 | 207.05 | 35.763 | 0.07 | 22.31 | 0.12 | 0.04 | 0.24 |
31 | 150.9 | 191.46 | 35.750 | 2.09 | 21.33 | 0.24 | 0.04 | 0.32 |
30 | 200.4 | 194.10 | 35.696 | 2.78 | 20.12 | 0.26 | 0.02 | 0.39 |
29 | 250.1 | 190.26 | 35.593 | 4.13 | 19.04 | 0.37 | < 0.02 | 0.66 |
28 | 300.9 | 205.04 | 35.517 | 3.42 | 17.94 | 0.30 | < 0.02 | 0.57 |
27 | 352.4 | 203.30 | 35.332 | 5.48 | 16.30 | 0.45 | < 0.02 | 1.04 |
26 | 402.3 | 188.69 | 34.955 | 11.90 | 13.78 | 0.90 | < 0.02 | 3.25 |
25 | 501.8 | 202.72 | 34.594 | 19.13 | 9.79 | 1.34 | < 0.02 | 5.97 |
24 | 600.8 | 236.79 | 34.395 | 22.71 | 7.26 | 1.53 | < 0.02 | 6.98 |
23 | 701.9 | 232.37 | 34.331 | 25.85 | 6.20 | 1.74 | < 0.02 | 11.38 |
22 | 801.3 | 201.38 | 34.337 | 30.24 | 5.39 | 2.05 | < 0.02 | 23.50 |
21 | 901.4 | 175.43 | 34.385 | 33.11 | 4.84 | 2.27 | < 0.02 | 38.08 |
20 | 1000.7 | 167.88 | 34.422 | 34.54 | 4.17 | 2.37 | < 0.02 | 51.55 |
19 | 1101.4 | 163.10 | 34.455 | 35.24 | 3.76 | 2.42 | < 0.02 | 61.97 |
18 | 1201.6 | 165.25 | 34.483 | 35.47 | 3.30 | 2.44 | < 0.02 | 70.32 |
17 | 1301.1 | 162.03 | 34.520 | 35.78 | 3.00 | 2.47 | < 0.02 | 80.47 |
16 | 1401.3 | 157.92 | 34.552 | 36.04 | 2.81 | 2.48 | < 0.02 | 89.29 |
15 | 1601.1 | 151.53 | 34.595 | 36.48 | 2.55 | 2.53 | < 0.02 | 104.03 |
14 | 1802.8 | 149.61 | 34.613 | 36.64 | 2.41 | 2.54 | < 0.02 | 110.92 |
13 | 2001.4 | 149.39 | 34.628 | 36.74 | 2.24 | 2.55 | < 0.02 | 116.80 |
12 | 2250 | 150.51 | 34.640 | 36.78 | 2.10 | 2.55 | < 0.02 | 121.56 |
11 | 2501.1 | 150.60 | 34.654 | 36.84 | 1.94 | 2.55 | < 0.02 | 127.88 |
10 | 2750.2 | 151.00 | 34.664 | 36.80 | 1.82 | 2.55 | < 0.02 | 132.50 |
9 | 3001.8 | 154.08 | 34.671 | 36.61 | 1.73 | 2.54 | < 0.02 | 135.09 |
8 | 3301.4 | 163.41 | 34.682 | 35.93 | 1.59 | 2.49 | < 0.02 | 133.56 |
7 | 3599.7 | 187.71 | 34.704 | 33.84 | 1.44 | 2.33 | < 0.02 | 120.61 |
6 | 4000.9 | 206.24 | 34.716 | 32.59 | 1.24 | 2.23 | < 0.02 | 115.12 |
5 | 4399.3 | 209.95 | 34.712 | 32.64 | 1.12 | 2.24 | < 0.02 | 118.65 |
4 | 4799.9 | 211.34 | 34.709 | 32.75 | 1.07 | 2.24 | < 0.02 | 121.04 |
3 | 5200.6 | 211.74 | 34.709 | 32.81 | 1.08 | 2.24 | < 0.02 | 122.19 |
2 | 5390.3 | 211.74 | 34.707 | 32.77 | 1.10 | 2.24 | < 0.02 | 122.32 |
1 | 5576.9 | 211.96 | 34.708 | 32.80 | 1.12 | 2.24 | < 0.02 | 122.40 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
Temperature CTD 20 - SN 6022 | Sea-Bird Electronics Inc | SBE3T | 6022 | Temperature (deg C) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |