Deployment Details
Survey: - IN2016_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 95
Gear: Autosal Salinometer,CTD 20 - SN 0552,CTD 23 - SN 1312,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 20 - SN 6022,Temperature CTD 21 - SN 6189,Transmissometer
When: 2016-06-11 22:53 to 2016-06-12 03:03 UTC
Where: 21° 30.0' S 170° 00.0' W
Maximum Depth (m): 5514.1
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
36 | 5.7 | 213.70 | 35.653 | < 0.02 | 24.47 | 0.08 | < 0.02 | 0.22 |
35 | 20.3 | 213.75 | 35.653 | < 0.02 | 24.48 | 0.08 | < 0.02 | 0.21 |
34 | 40.7 | 213.88 | 35.657 | < 0.02 | 24.47 | 0.08 | < 0.02 | 0.21 |
33 | 65.2 | 213.66 | 35.687 | < 0.02 | 24.42 | 0.08 | < 0.02 | 0.21 |
32 | 90.3 | 214.51 | 35.752 | 0.05 | 22.46 | 0.09 | 0.02 | 0.23 |
31 | 115.6 | 202.63 | 35.748 | 1.10 | 21.39 | 0.16 | 0.10 | 0.28 |
30 | 185.3 | 198.21 | 35.672 | 2.93 | 19.46 | 0.25 | < 0.02 | 0.46 |
29 | 235.2 | 194.59 | 35.515 | 4.45 | 18.16 | 0.37 | < 0.02 | 0.79 |
28 | 286 | 196.06 | 35.353 | 5.47 | 16.95 | 0.45 | < 0.02 | 1.05 |
27 | 336.1 | 189.27 | 35.170 | 8.53 | 15.54 | 0.67 | < 0.02 | 2.05 |
26 | 375.9 | 186.15 | 34.975 | 11.60 | 13.94 | 0.88 | < 0.02 | 3.21 |
25 | 464.8 | 194.23 | 34.678 | 17.17 | 10.73 | 1.22 | < 0.02 | 5.36 |
24 | 569.2 | 221.56 | 34.474 | 20.99 | 8.25 | 1.42 | < 0.02 | 6.30 |
23 | 667.9 | 225.31 | 34.361 | 24.79 | 6.80 | 1.66 | < 0.02 | 9.90 |
22 | 768 | 214.37 | 34.332 | 27.90 | 5.93 | 1.87 | < 0.02 | 16.17 |
21 | 867.4 | 198.21 | 34.341 | 30.50 | 5.29 | 2.05 | < 0.02 | 25.06 |
20 | 966.2 | 185.16 | 34.370 | 32.91 | 4.46 | 2.22 | < 0.02 | 38.99 |
19 | 1067 | 173.28 | 34.415 | 34.31 | 3.96 | 2.33 | < 0.02 | 51.81 |
18 | 1162.5 | 164.31 | 34.466 | 35.22 | 3.54 | 2.40 | < 0.02 | 65.49 |
17 | 1301.8 | 161.99 | 34.522 | 35.68 | 3.00 | 2.43 | < 0.02 | 80.78 |
16 | 1441.2 | 155.11 | 34.560 | 36.10 | 2.81 | 2.47 | < 0.02 | 92.22 |
15 | 1636.8 | 152.25 | 34.595 | 36.28 | 2.53 | 2.49 | < 0.02 | 103.67 |
14 | 1827.2 | < 0.02 | 34.613 | 36.51 | 2.38 | 2.51 | < 0.02 | 111.67 |
13 | 2065.9 | 149.44 | 34.630 | 36.66 | 2.23 | 2.52 | < 0.02 | 117.42 |
12 | 2315.4 | 149.93 | 34.642 | 36.69 | 2.08 | 2.52 | < 0.02 | 122.66 |
11 | 2565 | 150.11 | 34.654 | 36.72 | 1.95 | 2.52 | < 0.02 | 127.93 |
10 | 2816.3 | 150.78 | 34.663 | 36.66 | 1.84 | 2.52 | < 0.02 | 132.04 |
9 | 3082.9 | 154.93 | 34.673 | 36.39 | 1.72 | 2.50 | < 0.02 | 133.95 |
8 | 3364.9 | 173.95 | 34.693 | 34.75 | 1.60 | 2.38 | < 0.02 | 124.60 |
7 | 3701 | 198.25 | 34.717 | 32.68 | 1.43 | 2.22 | < 0.02 | 112.40 |
6 | 4090.6 | 207.54 | 34.715 | 32.45 | 1.18 | 2.20 | < 0.02 | 116.31 |
5 | 4490.3 | 210.76 | 34.710 | 32.61 | 1.07 | 2.21 | < 0.02 | 119.98 |
4 | 4894.9 | 211.60 | 34.708 | 32.73 | 1.05 | 2.22 | < 0.02 | 122.08 |
3 | 5295.1 | 211.56 | 34.707 | 32.70 | 1.09 | 2.22 | < 0.02 | 122.25 |
2 | 5421.7 | 211.78 | 34.707 | 32.70 | 1.10 | 2.22 | < 0.02 | 122.33 |
1 | 5514.1 | 211.69 | 34.708 | 32.70 | 1.11 | 2.22 | < 0.02 | 122.44 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
Temperature CTD 20 - SN 6022 | Sea-Bird Electronics Inc | SBE3T | 6022 | Temperature (deg C) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |