Deployment Details
Survey: - IN2016_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 94
Gear: Autosal Salinometer,CTD 20 - SN 0552,CTD 23 - SN 1312,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 20 - SN 6022,Temperature CTD 21 - SN 6189,Transmissometer
When: 2016-06-11 15:30 to 2016-06-11 20:06 UTC
Where: 22° 00.1' S 170° 00.0' W
Maximum Depth (m): 5731.9
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
36 | 4.1 | 213.66 | 35.674 | < 0.02 | 24.41 | 0.08 | < 0.02 | 0.19 |
35 | 20.2 | 213.61 | 35.674 | < 0.02 | 24.41 | 0.08 | < 0.02 | 0.20 |
34 | 59.8 | 213.79 | 35.691 | < 0.02 | 24.39 | 0.09 | < 0.02 | 0.22 |
33 | 85.3 | 213.61 | 35.699 | < 0.02 | 24.32 | 0.08 | < 0.02 | 0.21 |
32 | 113.5 | 214.55 | 35.763 | 0.05 | 22.44 | 0.08 | 0.02 | 0.21 |
31 | 165 | 198.70 | 35.700 | 2.34 | 20.13 | 0.24 | 0.02 | 0.37 |
30 | 214 | 200.13 | 35.595 | 2.93 | 18.98 | 0.28 | < 0.02 | 0.49 |
29 | 263.6 | 202.18 | 35.525 | 3.42 | 18.13 | 0.31 | < 0.02 | 0.58 |
28 | 314.7 | 193.02 | 35.330 | 6.44 | 16.50 | 0.53 | < 0.02 | 1.37 |
27 | 366.7 | 197.04 | 35.179 | 8.57 | 15.08 | 0.66 | < 0.02 | 1.98 |
26 | 436.3 | 191.28 | 34.817 | 14.37 | 12.16 | 1.07 | < 0.02 | 4.12 |
25 | 536.5 | 201.56 | 34.484 | 21.94 | 8.62 | 1.55 | < 0.02 | 8.36 |
24 | 636 | 197.67 | 34.387 | 26.34 | 7.07 | 1.83 | < 0.02 | 13.61 |
23 | 750.9 | 207.18 | 34.336 | 28.65 | 5.73 | 1.96 | < 0.02 | 18.59 |
22 | 836.1 | 195.70 | 34.344 | 30.83 | 5.17 | 2.12 | < 0.02 | 27.04 |
21 | 935.2 | 176.37 | 34.384 | 33.10 | 4.69 | 2.28 | < 0.02 | 39.47 |
20 | 1034.9 | 168.15 | 34.420 | 34.32 | 4.15 | 2.37 | < 0.02 | 51.38 |
19 | 1136.4 | 167.17 | 34.453 | 34.93 | 3.60 | 2.42 | < 0.02 | 62.15 |
18 | 1240.6 | 164.84 | 34.494 | 35.34 | 3.18 | 2.45 | < 0.02 | 73.26 |
17 | 1400.3 | 158.68 | 34.549 | 35.72 | 2.82 | 2.49 | < 0.02 | 88.38 |
16 | 1559.8 | 154.26 | 34.586 | 36.09 | 2.59 | 2.52 | < 0.02 | 100.15 |
15 | 1764.7 | 150.64 | 34.610 | 36.37 | 2.42 | 2.55 | < 0.02 | 109.60 |
14 | 1974.9 | 149.57 | 34.625 | 36.47 | 2.29 | 2.55 | < 0.02 | 114.41 |
13 | 2235 | 149.66 | 34.640 | 36.62 | 2.11 | 2.56 | < 0.02 | 121.02 |
12 | 2484.2 | 150.78 | 34.650 | 36.58 | 1.99 | 2.55 | < 0.02 | 125.04 |
11 | 2734.3 | 150.60 | 34.660 | 36.59 | 1.88 | 2.56 | < 0.02 | 130.29 |
10 | 2990.8 | 152.87 | 34.668 | 36.53 | 1.78 | 2.55 | < 0.02 | 133.48 |
9 | 3269.6 | 160.47 | 34.679 | 35.97 | 1.64 | 2.51 | < 0.02 | 133.78 |
8 | 3585.7 | 187.31 | 34.704 | 33.68 | 1.47 | 2.33 | < 0.02 | 119.86 |
7 | 3950.2 | 205.75 | 34.717 | 32.37 | 1.27 | 2.23 | < 0.02 | 114.09 |
6 | 4359.9 | 210.13 | 34.712 | 32.47 | 1.11 | 2.24 | < 0.02 | 118.49 |
5 | 4762.3 | 211.38 | 34.709 | 32.57 | 1.06 | 2.25 | < 0.02 | 120.97 |
4 | 5153.7 | 211.83 | 34.708 | 32.63 | 1.07 | 2.25 | < 0.02 | 122.04 |
3 | 5506.7 | 211.87 | 34.708 | 32.64 | 1.11 | 2.25 | < 0.02 | 122.20 |
2 | 5642.1 | 212.32 | 34.708 | 32.63 | 1.13 | 2.25 | < 0.02 | 122.25 |
1 | 5731.9 | 212.10 | 34.708 | 32.64 | 1.14 | 2.25 | < 0.02 | 122.09 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
Temperature CTD 20 - SN 6022 | Sea-Bird Electronics Inc | SBE3T | 6022 | Temperature (deg C) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |