Please login if you have access to particular applications.
Deployment Details
Survey: - IN2016_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 41
Gear: Autosal Salinometer,CTD 22,Conductivity CTD 22 - SN 3311,Fluorometer - CTD 22 - WET Labs ECO FLNTU,Licor - CTD 22 - SN 70371,Oxygen CTD 22-SBE 43-SN 3198,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - WET Labs ECO FLNTU,Temperature CTD 22 - SN 4722,Temperature CTD 22-SN 2751,Transmissometer - CTD 22 -CST-1421DR
When: 2016-05-20 06:49 to 2016-05-20 10:51 UTC
Where: 47° 06.9' S 170° 28.2' W
Maximum Depth (m): 5505.2
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|
| 36 | 4.4 | 270.91 | 34.669 | 6.72 | 11.41 | 0.62 | 0.33 | 1.01 |
| 35 | 35.2 | 270.87 | 34.667 | 6.71 | 11.40 | 0.62 | 0.33 | 0.98 |
| 34 | 59.8 | 270.87 | 34.670 | 6.72 | 11.40 | 0.61 | 0.33 | 0.99 |
| 33 | 84.4 | 270.87 | 34.671 | 6.73 | 11.40 | 0.62 | 0.33 | 0.99 |
| 32 | 114.2 | 265.51 | 34.710 | 7.98 | 11.26 | 0.68 | 0.25 | 1.37 |
| 31 | 165.8 | 249.61 | 34.794 | 11.95 | 10.48 | 0.89 | < 0.02 | 2.75 |
| 30 | 216.3 | 252.11 | 34.734 | 12.89 | 10.00 | 0.95 | < 0.02 | 3.07 |
| 29 | 265.4 | 256.93 | 34.695 | 13.55 | 9.74 | 0.99 | < 0.02 | 3.21 |
| 28 | 315.6 | 257.60 | 34.640 | 14.92 | 9.28 | 1.07 | < 0.02 | 3.59 |
| 27 | 365.4 | 258.19 | 34.591 | 16.12 | 8.95 | 1.14 | < 0.02 | 4.05 |
| 26 | 434.6 | 253.85 | 34.510 | 18.41 | 8.37 | 1.28 | < 0.02 | 4.99 |
| 25 | 534.7 | 259.75 | 34.434 | 19.87 | 7.76 | 1.38 | < 0.02 | 5.88 |
| 24 | 635.5 | 259.26 | 34.407 | 20.87 | 7.41 | 1.45 | < 0.02 | 6.98 |
| 23 | 735 | 250.24 | 34.375 | 22.83 | 7.00 | 1.57 | < 0.02 | 9.40 |
| 22 | 836.7 | 236.75 | 34.361 | 25.08 | 6.56 | 1.71 | < 0.02 | 12.94 |
| 21 | 935.8 | 224.73 | 34.351 | 27.19 | 6.02 | 1.85 | < 0.02 | 17.97 |
| 20 | 1036.7 | 216.38 | 34.337 | 29.60 | 5.26 | 2.01 | < 0.02 | 25.21 |
| 19 | 1137.2 | 209.15 | 34.338 | 31.48 | 4.52 | 2.15 | < 0.02 | 33.59 |
| 18 | 1235.6 | 202.58 | 34.359 | 32.81 | 4.01 | 2.25 | < 0.02 | 41.93 |
| 17 | 1336.2 | 199.72 | 34.369 | 33.70 | 3.55 | 2.31 | < 0.02 | 47.35 |
| 16 | 1466.8 | 193.61 | 34.405 | 34.51 | 3.18 | 2.37 | < 0.02 | 54.55 |
| 15 | 1566.2 | 190.52 | 34.427 | 34.76 | 3.06 | 2.39 | < 0.02 | 57.61 |
| 14 | 1695.1 | 186.82 | 34.459 | 34.92 | 2.95 | 2.40 | < 0.02 | 61.41 |
| 13 | 2085.7 | 180.52 | 34.546 | 34.84 | 2.69 | 2.40 | < 0.02 | 70.56 |
| 12 | 2333.7 | 179.05 | 34.602 | 34.45 | 2.57 | 2.37 | < 0.02 | 75.88 |
| 11 | 2551.7 | 173.37 | 34.646 | < 0.02 | 2.42 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 2834.8 | 187.98 | 34.711 | 32.74 | 2.20 | 2.26 | < 0.02 | 87.88 |
| 9 | 3100 | 195.48 | 34.732 | 32.17 | 1.99 | 2.22 | < 0.02 | 92.37 |
| 8 | 3400.4 | 201.02 | 34.735 | 32.08 | 1.72 | 2.22 | < 0.02 | 99.91 |
| 7 | 3723.5 | 205.17 | 34.727 | 32.39 | 1.44 | 2.24 | < 0.02 | 108.47 |
| 6 | 4134.8 | 210.04 | 34.716 | 32.76 | 1.18 | 2.26 | < 0.02 | 116.69 |
| 5 | 4534.3 | 212.59 | 34.710 | 32.99 | 1.04 | 2.28 | < 0.02 | 122.12 |
| 4 | 4934.7 | 344.96 | 34.706 | 33.05 | 1.02 | 2.29 | < 0.02 | 124.11 |
| 3 | 5335.4 | 214.19 | 34.705 | 33.14 | 1.03 | 2.29 | < 0.02 | 125.01 |
| 2 | 5405.7 | 214.19 | 34.704 | 33.11 | 1.04 | 2.29 | < 0.02 | 125.09 |
| 1 | 5505.2 | 214.28 | 34.705 | 33.10 | 1.05 | 2.29 | < 0.02 | 125.05 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
| CTD 22 | Seabird | Seabird SBE911 | 1243 | |
| Conductivity CTD 22 - SN 3311 | Seabird | SBE4C | 3311 | |
| Fluorometer - CTD 22 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 3698 | Fluorescence (arbitrary units) |
| Licor - CTD 22 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
| Oxygen CTD 22-SBE 43-SN 3198 | Seabird | SBE 43 | 3198 | Oxygen (µM) |
| Pressure CTD 22 | Digiquartz | 410K-134 | 1243 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| Scattering - CTD 22 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 3698 | Turbidity (%) |
| Temperature CTD 22 - SN 4722 | Sea-Bird Electronics Inc | SBE3T | 4722 | Temperature (deg C) |
| Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
| Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |