Deployment Details
Survey: - IN2016_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 17
Gear: Autosal Salinometer,CTD 22,Conductivity CTD 22 - SN 3311,Fluorometer - CTD 22 - WET Labs ECO FLNTU,Licor - CTD 22 - SN 70371,Oxygen CTD 22-SBE 43-SN 3198,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - WET Labs ECO FLNTU,Temperature CTD 22 - SN 4722,Temperature CTD 22-SN 2751,Transmissometer - CTD 22 -CST-1421DR
When: 2016-05-12 20:00 to 2016-05-13 00:57 UTC
Where: 58° 59.8' S 170° 00.0' W
Maximum Depth (m): 4755.9
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
36 | 6.1 | 328.70 | 33.892 | 27.41 | 2.52 | 1.89 | 0.33 | 13.58 |
35 | 20.2 | 328.44 | 33.893 | 27.41 | 2.52 | 1.89 | 0.33 | 13.62 |
34 | 40.4 | 328.62 | 33.895 | 27.39 | 2.52 | 1.89 | 0.33 | 13.65 |
33 | 65.2 | 328.17 | 33.899 | 27.43 | 2.51 | 1.90 | 0.33 | 13.66 |
32 | 91.4 | 328.53 | 33.901 | 27.43 | 2.51 | 1.90 | 0.33 | 13.73 |
31 | 135.6 | 328.53 | 33.903 | 27.45 | 2.49 | 1.90 | 0.33 | 13.89 |
30 | 187.6 | 309.28 | 33.985 | 29.53 | 2.03 | 2.02 | < 0.02 | 21.89 |
29 | 236.7 | 289.27 | 34.050 | 30.76 | 2.17 | 2.11 | < 0.02 | 27.68 |
28 | 287.4 | 272.21 | 34.112 | 32.03 | 2.13 | 2.19 | < 0.02 | 34.03 |
27 | 335.8 | 241.44 | 34.208 | 33.21 | 2.54 | 2.28 | < 0.02 | 40.73 |
26 | 387.2 | 232.51 | 34.249 | 33.88 | 2.43 | 2.32 | < 0.02 | 45.50 |
25 | 465.3 | 210.00 | 34.331 | 34.77 | 2.58 | 2.39 | < 0.02 | 52.82 |
24 | 563.4 | 190.30 | 34.423 | 35.32 | 2.66 | 2.43 | < 0.02 | 61.18 |
23 | 663.6 | 182.17 | 34.483 | 35.44 | 2.57 | 2.44 | < 0.02 | 67.14 |
22 | 764.5 | 178.60 | 34.532 | 35.24 | 2.52 | 2.43 | < 0.02 | 71.22 |
21 | 865.5 | 177.71 | 34.577 | 34.84 | 2.45 | 2.40 | < 0.02 | 74.49 |
20 | 965.2 | 178.33 | 34.619 | 34.34 | 2.38 | 2.37 | < 0.02 | 77.39 |
19 | 1065.7 | 180.88 | 34.653 | 33.73 | 2.33 | 2.32 | < 0.02 | 79.33 |
18 | 1164.6 | 182.35 | 34.675 | 33.33 | 2.27 | 2.30 | < 0.02 | 81.16 |
17 | 1266.2 | 184.94 | 34.697 | 32.96 | 2.20 | 2.27 | < 0.02 | 82.95 |
16 | 1362.2 | 187.31 | 34.708 | 32.64 | 2.16 | 2.25 | < 0.02 | 84.21 |
15 | 1467 | 189.76 | 34.720 | 32.34 | 2.09 | 2.22 | < 0.02 | 86.03 |
14 | 1563.4 | 191.91 | 34.727 | 32.22 | 2.03 | 2.21 | < 0.02 | 87.85 |
13 | 1735.5 | 195.39 | 34.736 | 31.96 | 1.91 | 2.20 | < 0.02 | 91.30 |
12 | 1901.1 | 198.38 | 34.738 | 31.91 | 1.76 | 2.20 | < 0.02 | 95.44 |
11 | 2101.6 | 200.97 | 34.737 | 32.02 | 1.61 | 2.20 | < 0.02 | 99.77 |
10 | 2301.3 | 203.16 | 34.733 | 32.12 | 1.47 | 2.22 | < 0.02 | 104.28 |
9 | 2502.7 | 205.40 | 34.729 | 32.29 | 1.33 | 2.23 | < 0.02 | 108.62 |
8 | 2900.3 | 208.66 | 34.719 | 32.57 | 1.12 | 2.25 | < 0.02 | 115.31 |
1 | 4755.9 | 213.66 | 34.705 | 33.10 | 0.95 | 2.29 | < 0.02 | 128.44 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
Conductivity CTD 22 - SN 3311 | Seabird | SBE4C | 3311 | |
Fluorometer - CTD 22 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 3698 | Fluorescence (arbitrary units) |
Licor - CTD 22 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
Oxygen CTD 22-SBE 43-SN 3198 | Seabird | SBE 43 | 3198 | Oxygen (µM) |
Pressure CTD 22 | Digiquartz | 410K-134 | 1243 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
Scattering - CTD 22 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 3698 | Turbidity (%) |
Temperature CTD 22 - SN 4722 | Sea-Bird Electronics Inc | SBE3T | 4722 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |