Please login if you have access to particular applications.
Deployment Details
Survey: - IN2016_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 15
Gear: Autosal Salinometer,CTD 22,Conductivity CTD 22 - SN 3311,Fluorometer - CTD 22 - WET Labs ECO FLNTU,Licor - CTD 22 - SN 70371,Oxygen CTD 22-SBE 43-SN 3198,Pressure CTD 22,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - WET Labs ECO FLNTU,Temperature CTD 22 - SN 4722,Temperature CTD 22-SN 2751,Transmissometer - CTD 22 -CST-1421DR
When: 2016-05-11 11:51 to 2016-05-11 15:25 UTC
Where: 60° 00.0' S 170° 01.2' W
Maximum Depth (m): 3881
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|
| 36 | 13.6 | 328.84 | 33.922 | 28.11 | 2.25 | 1.95 | 0.28 | 16.20 |
| 35 | 34.6 | 328.88 | 33.921 | 28.12 | 2.26 | 1.95 | 0.28 | 16.21 |
| 34 | 59.3 | 328.70 | 33.921 | 28.15 | 2.26 | 1.95 | 0.28 | 16.25 |
| 33 | 83.5 | 328.93 | 33.921 | 28.14 | 2.27 | 1.95 | 0.28 | 16.27 |
| 32 | 111.2 | 328.57 | 33.921 | 28.14 | 2.27 | 1.95 | 0.28 | 16.30 |
| 31 | 132.6 | 327.77 | 33.932 | 28.37 | 2.21 | 1.97 | 0.26 | 17.50 |
| 30 | 161.8 | 315.84 | 33.977 | 29.43 | 2.15 | 2.03 | 0.13 | 21.40 |
| 29 | 214.8 | 292.35 | 34.047 | 31.03 | 2.11 | 2.13 | < 0.02 | 28.42 |
| 28 | 264.6 | 263.41 | 34.135 | 32.34 | 2.35 | 2.22 | < 0.02 | 35.03 |
| 27 | 315.8 | 249.48 | 34.185 | 33.10 | 2.34 | 2.28 | < 0.02 | 39.91 |
| 26 | 364.1 | 240.77 | 34.223 | 33.76 | 2.32 | 2.32 | < 0.02 | 44.04 |
| 25 | 414.6 | 221.88 | 34.290 | 34.49 | 2.44 | 2.37 | < 0.02 | 49.91 |
| 24 | 464.3 | 212.10 | 34.330 | 34.87 | 2.50 | 2.40 | < 0.02 | 53.51 |
| 23 | 535.8 | 198.34 | 34.397 | 35.37 | 2.47 | 2.44 | < 0.02 | 60.24 |
| 22 | 635.2 | 185.83 | 34.463 | 35.59 | 2.51 | 2.46 | < 0.02 | 65.92 |
| 21 | 734.3 | 178.06 | 34.539 | 35.28 | 2.50 | 2.44 | < 0.02 | 71.82 |
| 20 | 834.5 | 177.57 | 34.582 | 34.90 | 2.44 | 2.41 | < 0.02 | 75.05 |
| 19 | 932.2 | 178.64 | 34.624 | 34.34 | 2.38 | 2.37 | < 0.02 | 77.65 |
| 18 | 1035 | 180.79 | 34.653 | 33.83 | 2.33 | 2.34 | < 0.02 | 79.55 |
| 17 | 1131.8 | 178.20 | 34.619 | 34.38 | 2.27 | 2.38 | < 0.02 | 77.31 |
| 16 | 1234.4 | 184.99 | 34.693 | 33.02 | 2.22 | 2.28 | < 0.02 | 82.64 |
| 15 | 1331.9 | 187.22 | 34.708 | 32.77 | 2.16 | 2.26 | < 0.02 | 84.10 |
| 14 | 1431.8 | 189.23 | 34.718 | 32.50 | 2.10 | 2.25 | < 0.02 | 85.71 |
| 13 | 1534.9 | 191.37 | 34.728 | 32.26 | 2.03 | 2.23 | < 0.02 | 87.75 |
| 12 | 1663.4 | 194.81 | 34.736 | 32.00 | 1.91 | 2.21 | < 0.02 | 90.67 |
| 11 | 1864.5 | 198.43 | 34.739 | 31.94 | 1.75 | 2.21 | < 0.02 | 95.37 |
| 10 | 2086.2 | 201.56 | 34.737 | 32.01 | 1.57 | 2.22 | < 0.02 | 100.67 |
| 9 | 2337.6 | 204.37 | 34.732 | 32.23 | 1.40 | 2.24 | < 0.02 | 106.10 |
| 8 | 2583.3 | 206.78 | 34.725 | 32.47 | 1.24 | 2.26 | < 0.02 | 111.48 |
| 7 | 2833.9 | 208.92 | 34.719 | 32.70 | 1.10 | 2.27 | < 0.02 | 115.92 |
| 6 | 3098.9 | 211.07 | 34.714 | 32.88 | 0.98 | 2.28 | < 0.02 | 120.02 |
| 5 | 3399.6 | 212.68 | 34.708 | 33.08 | 0.88 | 2.30 | < 0.02 | 126.00 |
| 4 | 3539.6 | 212.94 | 34.707 | 33.14 | 0.86 | 2.30 | < 0.02 | 127.71 |
| 3 | 3678.2 | 212.90 | 34.706 | 33.19 | 0.86 | 2.31 | < 0.02 | 129.12 |
| 2 | 3780.1 | 213.08 | 34.706 | 33.22 | 0.86 | 2.31 | < 0.02 | 129.99 |
| 1 | 3881 | 211.47 | 34.707 | 33.07 | 0.87 | 2.30 | < 0.02 | 124.41 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
| CTD 22 | Seabird | Seabird SBE911 | 1243 | |
| Conductivity CTD 22 - SN 3311 | Seabird | SBE4C | 3311 | |
| Fluorometer - CTD 22 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 3698 | Fluorescence (arbitrary units) |
| Licor - CTD 22 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
| Oxygen CTD 22-SBE 43-SN 3198 | Seabird | SBE 43 | 3198 | Oxygen (µM) |
| Pressure CTD 22 | Digiquartz | 410K-134 | 1243 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| Scattering - CTD 22 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 3698 | Turbidity (%) |
| Temperature CTD 22 - SN 4722 | Sea-Bird Electronics Inc | SBE3T | 4722 | Temperature (deg C) |
| Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
| Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |