Please login if you have access to particular applications.
Deployment Details
Survey: - IN2016_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 4
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20 - SN 3868,Fluorometer - CTD 20 - WET Labs ECO FLNTU,Licor - CTD 24 - SN 70111,Oxygen CTD 20-SBE 43-SN 3198,Pressure CTD 20,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - WET Labs ECO FLNTU,Temperature CTD 20 - SN 4722,Transmissometer - CTD 24 -CST-1421DR
When: 2016-05-05 13:20 to 2016-05-05 16:12 UTC
Where: 64° 59.9' S 169° 59.5' W
Maximum Depth (m): 2787.9
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|
| 35 | 34.8 | 344.43 | 34.079 | 29.20 | -0.35 | 2.06 | 0.29 | 56.98 |
| 36 | 36.7 | 344.29 | 34.086 | 29.24 | -0.36 | 2.07 | 0.29 | 57.00 |
| 34 | 60.9 | 344.34 | 34.086 | 29.22 | -0.35 | 2.06 | 0.28 | 56.89 |
| 33 | 86.1 | 341.25 | 34.098 | 29.24 | -0.34 | 2.07 | 0.28 | 58.38 |
| 32 | 109.9 | 274.84 | 34.311 | 33.01 | 0.35 | 2.31 | 0.12 | 69.62 |
| 31 | 139.4 | 220.04 | 34.514 | 34.37 | 0.96 | 2.40 | 0.02 | 80.63 |
| 30 | 160.2 | 204.82 | 34.580 | 34.33 | 1.26 | 2.40 | 0.02 | 83.62 |
| 29 | 183.1 | 189.85 | 34.649 | 34.11 | 1.63 | 2.38 | 0.02 | 86.57 |
| 28 | 205 | 185.66 | 34.677 | 33.83 | 1.81 | 2.36 | 0.02 | 87.12 |
| 27 | 238 | 186.59 | 34.685 | 33.68 | 1.77 | 2.35 | 0.02 | 88.06 |
| 26 | 261.4 | 187.40 | 34.699 | 33.29 | 1.84 | 2.32 | < 0.02 | 87.94 |
| 25 | 319.6 | 189.59 | 34.712 | 32.95 | 1.86 | 2.30 | < 0.02 | 88.63 |
| 24 | 362.8 | 190.84 | 34.719 | 32.66 | 1.84 | 2.28 | < 0.02 | 89.48 |
| 23 | 415.7 | 192.31 | 34.724 | 32.49 | 1.81 | 2.27 | < 0.02 | 90.96 |
| 22 | 464.5 | 193.38 | 34.727 | 32.43 | 1.77 | 2.27 | < 0.02 | 91.50 |
| 21 | 537.4 | 195.57 | 34.726 | 32.34 | 1.67 | 2.26 | < 0.02 | 92.91 |
| 20 | 633.6 | 198.12 | 34.730 | 32.28 | 1.58 | 2.26 | < 0.02 | 96.12 |
| 19 | 732.5 | 200.17 | 34.737 | 32.07 | 1.55 | 2.24 | < 0.02 | 98.46 |
| 18 | 832.4 | 200.62 | 34.730 | 32.37 | 1.41 | 2.26 | < 0.02 | 101.34 |
| 17 | 934.7 | 203.07 | 34.731 | 32.29 | 1.33 | 2.26 | < 0.02 | 105.07 |
| 16 | 1035 | 204.10 | 34.729 | 32.41 | 1.26 | 2.27 | < 0.02 | 107.33 |
| 15 | 1135.3 | 205.53 | 34.727 | 32.42 | 1.17 | 2.28 | < 0.02 | 110.23 |
| 14 | 1231.4 | 206.33 | 34.723 | 32.65 | 1.09 | 2.29 | < 0.02 | 112.51 |
| 13 | 1335.3 | 207.85 | 34.720 | 32.75 | 1.00 | 2.30 | < 0.02 | 115.42 |
| 12 | 1402.3 | 208.52 | 34.717 | 32.84 | 0.95 | 2.31 | < 0.02 | 117.21 |
| 11 | 1506.6 | 214.28 | 34.715 | 32.93 | 0.89 | 2.31 | < 0.02 | 118.88 |
| 10 | 1600.7 | 210.58 | 34.712 | 32.99 | 0.83 | 2.32 | < 0.02 | 121.66 |
| 9 | 1701.7 | 211.34 | 34.710 | 33.12 | 0.78 | 2.32 | < 0.02 | 123.88 |
| 8 | 1802.1 | 211.92 | 34.708 | 33.17 | 0.74 | 2.33 | < 0.02 | 125.97 |
| 7 | 2005.8 | 212.85 | 34.705 | 33.26 | 0.69 | 2.34 | < 0.02 | 129.21 |
| 6 | 2196.3 | 213.12 | 34.705 | 33.27 | 0.69 | 2.34 | < 0.02 | 129.59 |
| 5 | 2403.1 | 213.21 | 34.705 | 33.30 | 0.69 | 2.34 | < 0.02 | 128.98 |
| 4 | 2531.5 | 214.24 | 34.703 | 33.32 | 0.64 | 2.34 | < 0.02 | 128.77 |
| 3 | 2662.7 | 217.32 | 34.698 | 33.44 | 0.48 | 2.35 | < 0.02 | 129.81 |
| 2 | 2761.6 | 218.53 | 34.696 | 33.48 | 0.43 | 2.35 | < 0.02 | 130.06 |
| 1 | 2787.9 | 219.11 | 34.696 | 33.44 | 0.43 | 2.35 | < 0.02 | 130.01 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
| CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
| Conductivity CTD 20 - SN 3868 | Seabird | SBE4C | 3868 | |
| Fluorometer - CTD 20 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 3698 | Fluorescence (arbitrary units) |
| Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
| Oxygen CTD 20-SBE 43-SN 3198 | Seabird | SBE 43 | 3198 | Oxygen (µM) |
| Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| Scattering - CTD 22 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 3698 | Turbidity (%) |
| Temperature CTD 20 - SN 4722 | Sea-Bird Electronics Inc | SBE3T | 4722 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |