Please login if you have access to particular applications.
Deployment Details
Survey: - IN2016_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 3
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20 - SN 3868,Fluorometer - CTD 20 - WET Labs ECO FLNTU,Licor - CTD 24 - SN 70111,Oxygen CTD 20-SBE 43-SN 3198,Pressure CTD 20,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 22 - WET Labs ECO FLNTU,Temperature CTD 20 - SN 4722,Transmissometer - CTD 24 -CST-1421DR
When: 2016-05-05 03:20 to 2016-05-05 06:00 UTC
Where: 65° 39.9' S 170° 02.9' W
Maximum Depth (m): 3254.1
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|
| 35 | 20.9 | 353.40 | 34.065 | 29.03 | -1.30 | 2.03 | 0.24 | 65.06 |
| 34 | 22.8 | 353.54 | 34.065 | 29.01 | -1.30 | 2.03 | 0.24 | 65.06 |
| 33 | 48.5 | 353.36 | 34.067 | 29.00 | -1.28 | 2.03 | 0.24 | 64.88 |
| 32 | 75.3 | 352.96 | 34.068 | 28.94 | -1.26 | 2.03 | 0.24 | 64.68 |
| 31 | 100 | 327.10 | 34.137 | 29.89 | -0.96 | 2.10 | 0.21 | 68.41 |
| 30 | 125.3 | 235.54 | 34.491 | 33.24 | 0.14 | 2.32 | 0.04 | 84.18 |
| 29 | 148.9 | 211.51 | 34.589 | 33.49 | 0.83 | 2.34 | 0.02 | 88.30 |
| 28 | 168.4 | 201.20 | 34.640 | 33.50 | 1.14 | 2.34 | 0.02 | 90.59 |
| 27 | 201.2 | 196.11 | 34.684 | 33.22 | 1.39 | 2.32 | < 0.02 | 92.52 |
| 26 | 250.3 | 196.02 | 34.703 | 32.92 | 1.44 | 2.30 | < 0.02 | 94.40 |
| 25 | 299.9 | 196.15 | 34.712 | 32.80 | 1.44 | 2.30 | < 0.02 | 96.08 |
| 24 | 352.7 | 196.33 | 34.719 | 32.71 | 1.45 | 2.29 | < 0.02 | 97.58 |
| 23 | 374.9 | 196.69 | 34.721 | 32.67 | 1.43 | 2.29 | < 0.02 | 98.24 |
| 22 | 448.8 | 197.76 | 34.725 | 32.60 | 1.40 | 2.29 | < 0.02 | 100.66 |
| 21 | 599.5 | 198.92 | 34.728 | 32.64 | 1.30 | 2.29 | < 0.02 | 105.45 |
| 20 | 700.9 | 201.91 | 34.725 | 32.54 | 1.22 | 2.29 | < 0.02 | 106.97 |
| 19 | 799.4 | 203.74 | 34.726 | 32.55 | 1.17 | 2.29 | < 0.02 | 109.68 |
| 18 | 898.1 | 204.73 | 34.724 | 32.61 | 1.10 | 2.30 | < 0.02 | 111.88 |
| 17 | 1001.2 | 206.51 | 34.720 | 32.74 | 1.02 | 2.30 | < 0.02 | 114.55 |
| 16 | 1099.1 | 207.32 | 34.718 | 32.80 | 0.96 | 2.31 | < 0.02 | 116.44 |
| 15 | 1199.1 | 208.75 | 34.718 | 32.88 | 0.90 | 2.31 | < 0.02 | 118.50 |
| 14 | 1300.7 | 209.59 | 34.714 | 32.99 | 0.84 | 2.32 | < 0.02 | 120.64 |
| 13 | 1399.3 | 209.28 | 34.712 | 33.12 | 0.80 | 2.33 | < 0.02 | 122.99 |
| 12 | 1503.1 | 210.00 | 34.710 | 33.19 | 0.75 | 2.34 | < 0.02 | 124.25 |
| 11 | 1600.5 | 211.11 | 34.708 | 33.26 | 0.70 | 2.34 | < 0.02 | 126.37 |
| 10 | 1700.7 | 212.01 | 34.706 | 33.26 | 0.66 | 2.34 | < 0.02 | 126.83 |
| 9 | 1801.3 | 213.43 | 34.704 | 33.23 | 0.62 | 2.35 | < 0.02 | 127.57 |
| 8 | 1999.8 | 215.00 | 34.701 | 33.31 | 0.55 | 2.35 | < 0.02 | 128.44 |
| 7 | 2200.7 | 216.47 | 34.700 | 33.38 | 0.49 | 2.36 | < 0.02 | 129.56 |
| 6 | 2402 | 217.77 | 34.697 | 33.42 | 0.44 | 2.36 | < 0.02 | 129.71 |
| 5 | 2600.5 | 218.84 | 34.696 | 33.40 | 0.40 | 2.36 | < 0.02 | 130.19 |
| 4 | 2850.2 | 220.31 | 34.694 | 33.42 | 0.36 | 2.36 | < 0.02 | 130.23 |
| 3 | 3049.9 | 220.76 | 34.693 | 33.44 | 0.36 | 2.36 | < 0.02 | 130.47 |
| 2 | 3152.6 | 220.63 | 34.694 | 33.47 | 0.36 | 2.36 | < 0.02 | 130.63 |
| 1 | 3254.1 | 220.71 | 34.693 | 33.46 | 0.37 | 2.37 | < 0.02 | 130.53 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
| CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
| Conductivity CTD 20 - SN 3868 | Seabird | SBE4C | 3868 | |
| Fluorometer - CTD 20 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 3698 | Fluorescence (arbitrary units) |
| Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
| Oxygen CTD 20-SBE 43-SN 3198 | Seabird | SBE 43 | 3198 | Oxygen (µM) |
| Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| Scattering - CTD 22 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 3698 | Turbidity (%) |
| Temperature CTD 20 - SN 4722 | Sea-Bird Electronics Inc | SBE3T | 4722 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |