Please login if you have access to particular applications.
Deployment Details
Survey: - IN2016_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 1
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20 - SN 3868,Fluorometer - CTD 20 - WET Labs ECO FLNTU,Licor - CTD 24 - SN 70111,Oxygen CTD 20-SBE 43-SN 3198,Pressure CTD 20,Scattering - CTD 22 - WET Labs ECO FLNTU,Temperature CTD 20 - SN 4722,Transmissometer - CTD 24 -CST-1421DR
When: 2016-04-27 04:00 to 2016-04-27 06:59 UTC
Where: 45° 30.2' S 149° 23.9' E
Maximum Depth (m): 3029.1
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Salinity (psu) |
Temperature (deg C) |
|---|---|---|---|
| 3 | 3023.4 | 34.733 | 1.80 |
| 2 | 3023.6 | 34.733 | 1.80 |
| 1 | 3024.1 | 34.732 | 1.80 |
| 4 | 3024.2 | 34.732 | 1.80 |
| 8 | 3024.2 | 34.733 | 1.80 |
| 24 | 3024.3 | 34.733 | 1.80 |
| 13 | 3024.3 | 34.733 | 1.80 |
| 12 | 3024.5 | 34.732 | 1.80 |
| 7 | 3024.5 | 34.733 | 1.80 |
| 6 | 3024.6 | 34.732 | 1.80 |
| 23 | 3024.6 | 34.733 | 1.80 |
| 9 | 3024.6 | 34.732 | 1.80 |
| 15 | 3024.7 | 34.732 | 1.80 |
| 14 | 3024.8 | 34.732 | 1.80 |
| 5 | 3024.8 | < 0.02 | 1.80 |
| 16 | 3024.8 | 34.734 | 1.80 |
| 20 | 3025 | 34.733 | 1.80 |
| 25 | 3025 | 34.733 | 1.79 |
| 11 | 3025.2 | 34.732 | 1.80 |
| 10 | 3025.3 | 34.742 | 1.80 |
| 19 | 3025.4 | 34.733 | 1.80 |
| 21 | 3025.4 | 34.733 | 1.79 |
| 22 | 3025.4 | 34.733 | 1.79 |
| 28 | 3025.6 | 34.733 | 1.80 |
| 17 | 3025.8 | 34.733 | 1.79 |
| 18 | 3026 | 34.734 | 1.79 |
| 26 | 3026.3 | 34.511 | 1.79 |
| 31 | 3026.6 | 34.733 | 1.79 |
| 30 | 3026.7 | 34.733 | 1.79 |
| 27 | 3026.8 | 34.733 | 1.79 |
| 32 | 3028 | 34.733 | 1.79 |
| 29 | 3028 | 34.738 | 1.79 |
| 33 | 3028.7 | 34.733 | 1.79 |
| 34 | 3029 | 34.733 | 1.79 |
| 36 | 3029 | 34.733 | 1.79 |
| 35 | 3029.1 | 34.733 | 1.79 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
| CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
| Conductivity CTD 20 - SN 3868 | Seabird | SBE4C | 3868 | |
| Fluorometer - CTD 20 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 3698 | Fluorescence (arbitrary units) |
| Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
| Oxygen CTD 20-SBE 43-SN 3198 | Seabird | SBE 43 | 3198 | Oxygen (µM) |
| Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
| Scattering - CTD 22 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 3698 | Turbidity (%) |
| Temperature CTD 20 - SN 4722 | Sea-Bird Electronics Inc | SBE3T | 4722 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |