Please login if you have access to particular applications.
Deployment Details
Survey: - IN2015_C02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 30
Operation No.: 30
When: 2015-12-15 09:09 to 2015-12-15 09:42 UTC
Where:
33° 23.1' S
130° 17.2' E
to
33° 23.1' S
130° 17.3' E
Maximum Depth (m): 402
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2015 | 13.3 | < 0.02 | < 0.02 | < 0.02 | 19.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 13.6 | 241.39 | 35.869 | < 0.02 | 19.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2014 | 14.2 | < 0.02 | < 0.02 | 0.14 | 19.08 | 0.02 | 0.06 | < 0.02 | 0.82 |
2012 | 33.7 | < 0.02 | < 0.02 | 0.02 | 18.41 | 0.02 | 0.05 | < 0.02 | 0.77 |
2011 | 64.2 | < 0.02 | < 0.02 | 0.04 | 16.90 | 0.08 | 0.06 | < 0.02 | 0.63 |
2010 | 103.7 | < 0.02 | < 0.02 | < 0.02 | 14.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 103.7 | < 0.02 | < 0.02 | 1.11 | 14.64 | 0.22 | 0.03 | 0.13 | 0.81 |
2008 | 104 | 252.20 | 35.504 | < 0.02 | 14.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2006 | 123.5 | < 0.02 | < 0.02 | < 0.02 | 14.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2007 | 123.8 | < 0.02 | < 0.02 | < 0.02 | 14.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2005 | 123.8 | 247.51 | 35.457 | 2.41 | 14.36 | 0.30 | 0.05 | 0.06 | 0.90 |
2004 | 198.9 | 247.82 | 35.292 | 4.92 | 13.10 | 0.46 | 0.02 | < 0.02 | 1.25 |
2003 | 288.5 | 246.44 | 34.954 | 11.41 | 10.96 | 0.84 | 0.04 | < 0.02 | 2.62 |
2001 | 400.6 | 248.85 | 34.706 | < 0.02 | 9.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2002 | 401.2 | < 0.02 | < 0.02 | 16.11 | 9.42 | 1.12 | 0.03 | < 0.02 | 4.21 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20 - SN 3868 | Seabird | SBE4C | 3868 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 20-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Temperature CTD 20 - SN 4722 | Sea-Bird Electronics Inc | SBE3T | 4722 | Temperature (deg C) |