Deployment Details
Survey: - IN2015_C02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 25
Operation No.: 25
When: 2015-12-13 13:22 to 2015-12-13 13:55 UTC
Where:
33° 25.0' S
130° 38.8' E
to
33° 25.0' S
130° 38.9' E
Maximum Depth (m): 399
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2014 | 11.2 | < 0.02 | < 0.02 | < 0.02 | 18.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2012 | 11.4 | 242.87 | 35.837 | < 0.02 | 18.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 11.4 | < 0.02 | < 0.02 | < 0.02 | 18.55 | 0.04 | < 0.02 | < 0.02 | 0.61 |
2011 | 31.7 | < 0.02 | < 0.02 | < 0.02 | 18.25 | 0.07 | < 0.02 | < 0.02 | 0.54 |
2009 | 76.3 | < 0.02 | < 0.02 | 0.02 | 15.35 | 0.14 | 0.02 | < 0.02 | 0.77 |
2008 | 76.9 | < 0.02 | < 0.02 | < 0.02 | 15.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2010 | 77 | < 0.02 | < 0.02 | < 0.02 | 15.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2007 | 92.1 | 259.17 | 35.527 | 0.08 | 14.93 | 0.16 | 0.05 | 0.04 | 0.74 |
2005 | 121.3 | < 0.02 | < 0.02 | 2.14 | 14.34 | 0.29 | < 0.02 | 0.07 | 0.89 |
2006 | 121.9 | < 0.02 | < 0.02 | < 0.02 | 14.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2004 | 122 | < 0.02 | < 0.02 | < 0.02 | 14.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2003 | 201.6 | 245.59 | 35.325 | 4.67 | 13.39 | 0.45 | < 0.02 | 0.02 | 1.40 |
2002 | 302.2 | 245.68 | 34.882 | 12.82 | 10.59 | 0.93 | < 0.02 | 0.02 | 3.20 |
2001 | 399.1 | < 0.02 | < 0.02 | < 0.02 | 9.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20 - SN 3868 | Seabird | SBE4C | 3868 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 20-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Temperature CTD 20 - SN 4722 | Sea-Bird Electronics Inc | SBE3T | 4722 | Temperature (deg C) |