Deployment Details
Survey: - IN2015_C02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 8
Operation No.: 8
When: 2015-12-02 17:58 to 2015-12-02 18:51 UTC
Where:
36° 35.7' S
136° 00.9' E
to
36° 35.7' S
136° 00.7' E
Maximum Depth (m): 807
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2013 | 13.2 | 258.19 | 35.446 | < 0.02 | 15.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 13.9 | < 0.02 | < 0.02 | < 0.02 | 15.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2014 | 14.2 | < 0.02 | < 0.02 | 4.59 | 15.81 | 0.43 | 0.05 | 0.04 | 1.71 |
2012 | 33.4 | < 0.02 | < 0.02 | 0.02 | 15.68 | 0.15 | 0.07 | < 0.02 | 0.78 |
2011 | 58.4 | < 0.02 | < 0.02 | < 0.02 | 14.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 58.6 | < 0.02 | < 0.02 | 1.06 | 14.05 | 0.23 | 0.04 | 0.14 | 0.99 |
2010 | 59.1 | < 0.02 | < 0.02 | < 0.02 | 14.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2008 | 89.2 | 258.14 | 35.361 | 3.64 | 13.14 | 0.38 | 0.06 | 0.19 | 1.36 |
2006 | 118.2 | < 0.02 | < 0.02 | < 0.02 | 13.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2005 | 119.2 | < 0.02 | < 0.02 | 4.28 | 13.12 | 0.41 | 0.04 | 0.03 | 1.58 |
2007 | 120.9 | < 0.02 | < 0.02 | < 0.02 | 13.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2004 | 206.3 | < 0.02 | < 0.02 | 5.27 | 12.61 | 0.47 | 0.02 | < 0.02 | 1.87 |
2003 | 304.6 | < 0.02 | < 0.02 | 8.01 | 11.91 | 0.63 | 0.04 | 0.02 | 2.47 |
2002 | 405.9 | 250.99 | 34.825 | 13.43 | 10.19 | 0.96 | 0.05 | < 0.02 | 3.78 |
2001 | 800.7 | 201.60 | 34.433 | 27.90 | 6.26 | 1.89 | 0.05 | < 0.02 | 22.61 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20 - SN 3868 | Seabird | SBE4C | 3868 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 20-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
Temperature CTD 20 - SN 4722 | Sea-Bird Electronics Inc | SBE3T | 4722 | Temperature (deg C) |