Deployment Details
Survey: - IN2015_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 42
Gear: Altimeter-163,Autosal Salinometer,CTD 20 - SN 0552,CTD 22,CTD 23 - SN 1312,Chelsea Tech Fluorometer,Conductivity CTD 20 - SN 3868,Conductivity CTD 22-SN 3908,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Licor - LI-190SL Q46071,Oxygen CTD 20-SBE 43-SN 1794,Pressure CTD 20,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Teledyne Altimeter PA 500kHz,Temperature CTD 20 - SN 4722,Temperature CTD 21 - SN 6189,Temperature CTD 22-SN 2751,Transmissometer,Transmissometer - CTD 24 -CST-1421DR
When: 2015-06-15 20:41 to 2015-06-15 21:36 UTC
Where: 32° 00.9' S 153° 15.0' E
Maximum Depth (m): 1012.5
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1022 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 22.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1024 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 22.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1062 | 6.7 | 220.22 | 35.623 | 0.09 | 22.40 | 0.08 | 0.02 | 0.02 | 0.50 |
1052 | 6.7 | < 0.02 | < 0.02 | < 0.02 | 22.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1023 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 22.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1042 | 7.3 | < 0.02 | < 0.02 | < 0.02 | 22.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1066 | 7.3 | < 0.02 | < 0.02 | < 0.02 | 22.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1016 | 30.5 | 220.00 | 35.622 | 0.08 | 22.40 | 0.07 | < 0.02 | 0.03 | 0.48 |
1064 | 31 | < 0.02 | < 0.02 | < 0.02 | 22.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1015 | 45.4 | < 0.02 | < 0.02 | < 0.02 | 22.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1063 | 45.8 | 216.92 | 35.680 | 0.35 | 22.26 | 0.10 | 0.06 | 0.07 | 0.50 |
1059 | 45.9 | < 0.02 | < 0.02 | < 0.02 | 22.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1055 | 46.1 | < 0.02 | < 0.02 | < 0.02 | 22.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1010 | 65.2 | < 0.02 | < 0.02 | < 0.02 | 21.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1054 | 65.7 | 220.40 | 35.687 | 0.19 | 21.93 | 0.08 | 0.08 | 0.08 | 0.47 |
1071 | 66.7 | < 0.02 | < 0.02 | < 0.02 | 21.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1007 | 105.3 | < 0.02 | < 0.02 | < 0.02 | 21.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1008 | 105.4 | < 0.02 | < 0.02 | < 0.02 | 21.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1006 | 105.8 | 196.73 | 35.682 | 2.83 | 21.14 | 0.28 | 0.02 | 0.06 | 0.89 |
1001 | 205.5 | 204.10 | 35.617 | 4.51 | 18.15 | 0.39 | < 0.02 | 0.02 | 1.21 |
1004 | 307.2 | 189.81 | 35.284 | 10.75 | 15.00 | 0.78 | 0.06 | < 0.02 | 3.44 |
1057 | 407.3 | 198.29 | 35.032 | 14.90 | 12.29 | 1.04 | 0.03 | < 0.02 | 5.27 |
1003 | 508.3 | 202.67 | 34.808 | 18.88 | 10.25 | 1.29 | 0.03 | < 0.02 | 7.54 |
1002 | 1012.5 | 190.26 | 34.448 | 30.60 | 5.34 | 2.10 | 0.03 | < 0.02 | 37.99 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Altimeter-163 | Benthos | 163 | Altitude(m) | |
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 20 - SN 3868 | Seabird | SBE4C | 3868 | |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Oxygen CTD 20-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
Teledyne Altimeter PA 500kHz | Teledyne | PA 500kHz | 228403 | Altitude(m) |
Temperature CTD 20 - SN 4722 | Sea-Bird Electronics Inc | SBE3T | 4722 | Temperature (deg C) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) | ||
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |