Deployment Details
Survey: - IN2015_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 35
Gear: Altimeter-163,Autosal Salinometer,CTD 20 - SN 0552,CTD 22,CTD 23 - SN 1312,Chelsea Tech Fluorometer,Conductivity CTD 20 - SN 3868,Conductivity CTD 22-SN 3908,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Licor - LI-190SL Q46071,Oxygen CTD 20-SBE 43-SN 1794,Pressure CTD 20,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Teledyne Altimeter PA 500kHz,Temperature CTD 20 - SN 4722,Temperature CTD 21 - SN 6189,Temperature CTD 22-SN 2751,Transmissometer,Transmissometer - CTD 24 -CST-1421DR
When: 2015-06-11 13:20 to 2015-06-11 14:20 UTC
Where: 32° 40.7' S 153° 35.5' E
Maximum Depth (m): 1012.8
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1042 | 7 | 221.83 | 35.679 | 0.12 | 21.67 | 0.07 | 0.10 | 0.03 | 0.45 |
1022 | 7.4 | < 0.02 | < 0.02 | < 0.02 | 21.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1023 | 7.8 | < 0.02 | < 0.02 | < 0.02 | 21.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1024 | 7.9 | < 0.02 | < 0.02 | < 0.02 | 21.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1052 | 25.9 | < 0.02 | < 0.02 | < 0.02 | 21.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1062 | 26 | < 0.02 | < 0.02 | < 0.02 | 21.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1066 | 26.3 | < 0.02 | < 0.02 | < 0.02 | 21.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1064 | 26.7 | 221.83 | 35.678 | 0.11 | 21.67 | 0.07 | 0.07 | 0.03 | 0.46 |
1055 | 51.5 | 221.56 | 35.677 | 0.12 | 21.68 | 0.07 | 0.08 | 0.04 | 0.46 |
1059 | 51.8 | < 0.02 | < 0.02 | < 0.02 | 21.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1015 | 51.9 | < 0.02 | < 0.02 | < 0.02 | 21.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1016 | 52.3 | < 0.02 | < 0.02 | < 0.02 | 21.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1010 | 75.6 | 221.12 | 35.680 | 0.14 | 21.69 | 0.07 | 0.08 | 0.04 | 0.46 |
1063 | 76.8 | < 0.02 | < 0.02 | < 0.02 | 21.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1071 | 76.9 | < 0.02 | < 0.02 | < 0.02 | 21.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1007 | 111.2 | < 0.02 | < 0.02 | < 0.02 | 20.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1008 | 111.3 | < 0.02 | < 0.02 | < 0.02 | 20.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1001 | 111.7 | 194.14 | 35.648 | 3.43 | 20.55 | 0.32 | 0.12 | 0.08 | 1.12 |
1006 | 111.8 | < 0.02 | < 0.02 | < 0.02 | 20.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1054 | 112.4 | < 0.02 | < 0.02 | < 0.02 | 20.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1004 | 206.9 | 190.48 | 35.492 | 7.08 | 17.20 | 0.53 | 0.05 | 0.02 | 2.11 |
1057 | 306.5 | 193.25 | 35.354 | 9.34 | 15.42 | 0.68 | 0.06 | < 0.02 | 3.00 |
1003 | 509 | 200.44 | 34.868 | 17.70 | 10.73 | 1.21 | 0.06 | < 0.02 | 6.82 |
1002 | 1012.8 | 187.93 | 34.450 | 31.00 | 5.15 | 2.13 | 0.08 | < 0.02 | 41.09 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Altimeter-163 | Benthos | 163 | Altitude(m) | |
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 20 - SN 3868 | Seabird | SBE4C | 3868 | |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Oxygen CTD 20-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
Teledyne Altimeter PA 500kHz | Teledyne | PA 500kHz | 228403 | Altitude(m) |
Temperature CTD 20 - SN 4722 | Sea-Bird Electronics Inc | SBE3T | 4722 | Temperature (deg C) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) | ||
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |