Deployment Details
Survey: - IN2015_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 31
Gear: Altimeter-163,Autosal Salinometer,CTD 20 - SN 0552,CTD 22,CTD 23 - SN 1312,Chelsea Tech Fluorometer,Conductivity CTD 20 - SN 3868,Conductivity CTD 22-SN 3908,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Licor - LI-190SL Q46071,Oxygen CTD 20-SBE 43-SN 1794,Pressure CTD 20,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Teledyne Altimeter PA 500kHz,Temperature CTD 20 - SN 4722,Temperature CTD 21 - SN 6189,Temperature CTD 22-SN 2751,Transmissometer,Transmissometer - CTD 24 -CST-1421DR
When: 2015-06-11 04:15 to 2015-06-11 05:07 UTC
Where: 32° 35.4' S 153° 11.2' E
Maximum Depth (m): 999.5
Bottle Data
| Bottle Number | Pressure | Oxygen (µM) | Salinity (psu) | Nitrate (µM) | Temperature (deg C) | Orthophosphate (µM) | Ammonia (µM) | Nitrite (µM) | Silicate (µM) | 
|---|---|---|---|---|---|---|---|---|---|
| 1022 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 21.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1023 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 21.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1042 | 6.3 | 225.72 | 35.603 | 0.41 | 21.02 | 0.10 | 0.07 | 0.18 | 0.79 | 
| 1024 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 21.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1066 | 32 | < 0.02 | < 0.02 | < 0.02 | 21.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1052 | 32.1 | < 0.02 | < 0.02 | < 0.02 | 21.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1062 | 32.1 | < 0.02 | < 0.02 | < 0.02 | 21.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1064 | 32.2 | 225.54 | 35.601 | 0.42 | 21.03 | 0.10 | 0.09 | 0.18 | 0.78 | 
| 1015 | 56.3 | < 0.02 | < 0.02 | < 0.02 | 21.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1059 | 56.4 | < 0.02 | < 0.02 | < 0.02 | 21.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1055 | 56.5 | 224.11 | 35.601 | 0.47 | 21.03 | 0.11 | 0.10 | 0.20 | 0.79 | 
| 1016 | 56.6 | < 0.02 | < 0.02 | < 0.02 | 21.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1071 | 81.4 | < 0.02 | < 0.02 | < 0.02 | 20.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1054 | 81.6 | 217.68 | 35.567 | 1.39 | 20.99 | 0.18 | 0.09 | 0.33 | 1.08 | 
| 1063 | 81.8 | < 0.02 | < 0.02 | < 0.02 | 20.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1010 | 82 | < 0.02 | < 0.02 | < 0.02 | 21.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1008 | 106.5 | < 0.02 | < 0.02 | < 0.02 | 19.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1006 | 106.9 | < 0.02 | < 0.02 | < 0.02 | 19.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1007 | 106.9 | < 0.02 | < 0.02 | < 0.02 | 19.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1001 | 106.9 | 189.27 | 35.572 | 5.22 | 19.39 | 0.43 | 0.07 | 0.07 | 1.55 | 
| 1004 | 207.6 | 191.95 | 35.404 | 8.75 | 16.03 | 0.64 | 0.07 | < 0.02 | 2.47 | 
| 1057 | 305.5 | 195.30 | 35.240 | 11.36 | 14.12 | 0.80 | 0.08 | < 0.02 | 3.45 | 
| 1003 | 493.8 | 202.72 | 34.809 | 18.61 | 10.22 | 1.25 | 0.07 | < 0.02 | 6.97 | 
| 1002 | 999.5 | 188.16 | 34.449 | 30.85 | 5.21 | 2.10 | 0.09 | < 0.02 | 39.44 | 
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring | 
|---|---|---|---|---|
| Altimeter-163 | Benthos | 163 | Altitude(m) | |
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) | 
| CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
| CTD 22 | Seabird | Seabird SBE911 | 1243 | |
| CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
| Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) | 
| Conductivity CTD 20 - SN 3868 | Seabird | SBE4C | 3868 | |
| Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
| Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) | 
| Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) | 
| Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) | 
| Oxygen CTD 20-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) | 
| Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) | 
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) | 
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| Teledyne Altimeter PA 500kHz | Teledyne | PA 500kHz | 228403 | Altitude(m) | 
| Temperature CTD 20 - SN 4722 | Sea-Bird Electronics Inc | SBE3T | 4722 | Temperature (deg C) | 
| Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) | 
| Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) | 
| Transmissometer | SeaTech | Transmittance (%) | ||
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |