Deployment Details
Survey: - IN2015_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 20
Gear: Altimeter-163,Autosal Salinometer,CTD 20 - SN 0552,CTD 22,CTD 23 - SN 1312,Chelsea Tech Fluorometer,Conductivity CTD 20 - SN 3868,Conductivity CTD 22-SN 3908,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Licor - LI-190SL Q46071,Oxygen CTD 20-SBE 43-SN 1794,Pressure CTD 20,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Teledyne Altimeter PA 500kHz,Temperature CTD 20 - SN 4722,Temperature CTD 21 - SN 6189,Temperature CTD 22-SN 2751,Transmissometer,Transmissometer - CTD 24 -CST-1421DR
When: 2015-06-09 11:28 to 2015-06-09 12:07 UTC
Where: 32° 39.8' S 153° 13.0' E
Maximum Depth (m): 500.7
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1042 | 7.4 | 226.65 | 35.549 | 0.66 | 20.54 | 0.14 | < 0.02 | 0.20 | 1.26 |
1024 | 7.4 | < 0.02 | < 0.02 | < 0.02 | 20.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1023 | 7.5 | < 0.02 | < 0.02 | < 0.02 | 20.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1022 | 7.9 | < 0.02 | < 0.02 | < 0.02 | 20.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1064 | 29.5 | 228.71 | 35.555 | 0.53 | 20.47 | 0.14 | 0.03 | 0.16 | 1.25 |
1066 | 29.5 | < 0.02 | < 0.02 | < 0.02 | 20.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1062 | 29.7 | < 0.02 | < 0.02 | < 0.02 | 20.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1052 | 29.9 | < 0.02 | < 0.02 | < 0.02 | 20.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1059 | 44.1 | < 0.02 | < 0.02 | < 0.02 | 20.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1015 | 44.3 | < 0.02 | < 0.02 | < 0.02 | 20.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1055 | 44.4 | 226.52 | 35.545 | 0.79 | 20.40 | 0.15 | 0.04 | 0.20 | 1.34 |
1016 | 44.5 | < 0.02 | < 0.02 | < 0.02 | 20.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1054 | 78.6 | 191.64 | 35.516 | 5.61 | 18.60 | 0.47 | 0.04 | 0.08 | 2.07 |
1071 | 78.8 | < 0.02 | < 0.02 | < 0.02 | 18.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1063 | 78.9 | < 0.02 | < 0.02 | < 0.02 | 18.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1010 | 79.2 | < 0.02 | < 0.02 | < 0.02 | 18.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1008 | 103.5 | < 0.02 | < 0.02 | < 0.02 | 17.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1006 | 103.6 | < 0.02 | < 0.02 | < 0.02 | 17.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1001 | 104 | 188.42 | 35.470 | 7.15 | 17.36 | 0.57 | 0.05 | 0.03 | 2.39 |
1007 | 104.1 | < 0.02 | < 0.02 | < 0.02 | 17.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1004 | 203.7 | 194.28 | 35.355 | 9.09 | 15.43 | 0.69 | 0.05 | < 0.02 | 2.98 |
1057 | 302.4 | 195.21 | 35.143 | 12.66 | 13.25 | 0.91 | 0.07 | < 0.02 | 4.45 |
1003 | 404.3 | 201.42 | 34.843 | 17.96 | 10.51 | 1.24 | 0.06 | < 0.02 | 7.18 |
1002 | 500.7 | 203.12 | 34.714 | 20.50 | 9.42 | 1.41 | 0.05 | < 0.02 | 9.40 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Altimeter-163 | Benthos | 163 | Altitude(m) | |
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 20 - SN 3868 | Seabird | SBE4C | 3868 | |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Oxygen CTD 20-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
Teledyne Altimeter PA 500kHz | Teledyne | PA 500kHz | 228403 | Altitude(m) |
Temperature CTD 20 - SN 4722 | Sea-Bird Electronics Inc | SBE3T | 4722 | Temperature (deg C) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) | ||
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |