Deployment Details
Survey: - IN2015_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 17
Gear: Altimeter-163,Autosal Salinometer,CTD 20 - SN 0552,CTD 22,CTD 23 - SN 1312,Chelsea Tech Fluorometer,Conductivity CTD 20 - SN 3868,Conductivity CTD 22-SN 3908,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Licor - LI-190SL Q46071,Oxygen CTD 20-SBE 43-SN 1794,Pressure CTD 20,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Teledyne Altimeter PA 500kHz,Temperature CTD 20 - SN 4722,Temperature CTD 21 - SN 6189,Temperature CTD 22-SN 2751,Transmissometer,Transmissometer - CTD 24 -CST-1421DR
When: 2015-06-07 10:05 to 2015-06-07 11:09 UTC
Where: 30° 02.1' S 153° 36.3' E
Maximum Depth (m): 1465.3
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1022 | 7.2 | < 0.02 | < 0.02 | < 0.02 | 22.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1023 | 7.5 | 219.42 | 35.677 | 0.06 | 22.38 | 0.06 | 0.11 | 0.03 | 0.35 |
1052 | 30.6 | < 0.02 | < 0.02 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1042 | 30.9 | 219.78 | 35.677 | 0.07 | 22.39 | 0.07 | 0.11 | 0.03 | 0.33 |
1062 | 31.1 | < 0.02 | < 0.02 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1066 | 31.2 | < 0.02 | < 0.02 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1064 | 55.7 | 218.88 | 35.674 | 0.10 | 22.39 | 0.07 | 0.12 | 0.03 | 0.34 |
1016 | 55.8 | < 0.02 | < 0.02 | < 0.02 | 22.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1059 | 105.5 | < 0.02 | < 0.02 | < 0.02 | 20.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1055 | 105.7 | < 0.02 | < 0.02 | < 0.02 | 20.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1015 | 106.2 | 193.02 | 35.676 | 3.26 | 20.77 | 0.32 | 0.10 | 0.04 | 0.74 |
1063 | 508.1 | 198.96 | 34.884 | 17.53 | 10.97 | 1.21 | 0.11 | < 0.02 | 6.61 |
1071 | 508.7 | < 0.02 | < 0.02 | < 0.02 | 10.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1010 | 509.1 | < 0.02 | < 0.02 | < 0.02 | 10.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1007 | 1011.4 | < 0.02 | < 0.02 | < 0.02 | 4.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1008 | 1011.5 | < 0.02 | < 0.02 | < 0.02 | 4.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1054 | 1011.8 | 184.72 | 34.458 | 31.61 | 4.97 | 2.17 | 0.09 | < 0.02 | 44.71 |
1001 | 1265.3 | 165.51 | 34.522 | 34.67 | 3.78 | 2.40 | 0.15 | < 0.02 | 73.57 |
1006 | 1265.6 | < 0.02 | < 0.02 | < 0.02 | 3.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1004 | 1265.8 | < 0.02 | < 0.02 | < 0.02 | 3.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1003 | 1464.7 | < 0.02 | < 0.02 | < 0.02 | 3.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1002 | 1465.3 | 158.19 | 34.589 | 35.87 | 3.00 | 2.49 | 0.17 | < 0.02 | 92.61 |
1057 | 1465.3 | < 0.02 | < 0.02 | < 0.02 | 3.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Altimeter-163 | Benthos | 163 | Altitude(m) | |
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 20 - SN 3868 | Seabird | SBE4C | 3868 | |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Oxygen CTD 20-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
Teledyne Altimeter PA 500kHz | Teledyne | PA 500kHz | 228403 | Altitude(m) |
Temperature CTD 20 - SN 4722 | Sea-Bird Electronics Inc | SBE3T | 4722 | Temperature (deg C) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) | ||
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |