Deployment Details
Survey: - IN2015_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 12
Gear: Altimeter-163,Autosal Salinometer,CTD 20 - SN 0552,CTD 22,CTD 23 - SN 1312,Chelsea Tech Fluorometer,Conductivity CTD 20 - SN 3868,Conductivity CTD 22-SN 3908,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Licor - LI-190SL Q46071,Oxygen CTD 20-SBE 43-SN 1794,Pressure CTD 20,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Teledyne Altimeter PA 500kHz,Temperature CTD 20 - SN 4722,Temperature CTD 21 - SN 6189,Temperature CTD 22-SN 2751,Transmissometer,Transmissometer - CTD 24 -CST-1421DR
When: 2015-06-06 11:59 to 2015-06-06 12:53 UTC
Where: 28° 35.9' S 155° 22.0' E
Maximum Depth (m): 1004.2
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1042 | 5.3 | 217.99 | 35.612 | 0.37 | 22.22 | 0.11 | 0.18 | 0.04 | 0.50 |
1024 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 22.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1022 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 22.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1023 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 22.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1052 | 30.2 | < 0.02 | < 0.02 | < 0.02 | 22.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1066 | 30.2 | < 0.02 | < 0.02 | < 0.02 | 22.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1064 | 30.4 | 217.95 | 35.610 | 0.35 | 22.23 | 0.11 | 0.19 | 0.04 | 0.52 |
1062 | 30.4 | < 0.02 | < 0.02 | < 0.02 | 22.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1016 | 53.7 | < 0.02 | < 0.02 | < 0.02 | 22.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1015 | 54.2 | < 0.02 | < 0.02 | < 0.02 | 22.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1055 | 54.3 | 216.87 | 35.610 | 0.41 | 22.23 | 0.11 | 0.19 | 0.05 | 0.52 |
1059 | 54.3 | < 0.02 | < 0.02 | < 0.02 | 22.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1054 | 86.7 | 176.68 | 35.615 | 5.02 | 21.13 | 0.42 | 0.09 | 0.16 | 1.66 |
1063 | 87.1 | < 0.02 | < 0.02 | < 0.02 | 21.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1071 | 87.3 | < 0.02 | < 0.02 | < 0.02 | 21.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1010 | 87.7 | < 0.02 | < 0.02 | < 0.02 | 20.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1007 | 104.8 | < 0.02 | < 0.02 | < 0.02 | 19.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1006 | 104.8 | < 0.02 | < 0.02 | < 0.02 | 19.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1001 | 105 | 165.11 | 35.597 | 7.20 | 19.73 | 0.57 | 0.08 | 0.05 | 2.08 |
1008 | 105.6 | < 0.02 | < 0.02 | < 0.02 | 19.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1004 | 249.8 | 179.40 | 35.225 | 11.83 | 14.83 | 0.87 | 0.09 | < 0.02 | 4.23 |
1057 | 344.3 | 192.13 | < 0.02 | 14.57 | 12.53 | 1.02 | 0.08 | < 0.02 | 5.25 |
1053 | 505.2 | 203.92 | 34.738 | 19.76 | 9.64 | 1.37 | 0.10 | < 0.02 | 8.38 |
1002 | 1004.2 | 183.78 | 34.459 | 31.46 | 4.87 | 2.19 | 0.11 | < 0.02 | 46.53 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Altimeter-163 | Benthos | 163 | Altitude(m) | |
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 20 - SN 3868 | Seabird | SBE4C | 3868 | |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Oxygen CTD 20-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
Teledyne Altimeter PA 500kHz | Teledyne | PA 500kHz | 228403 | Altitude(m) |
Temperature CTD 20 - SN 4722 | Sea-Bird Electronics Inc | SBE3T | 4722 | Temperature (deg C) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) | ||
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |