Deployment Details
Survey: - IN2015_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 7
Gear: Altimeter-163,Autosal Salinometer,CTD 20 - SN 0552,CTD 22,CTD 23 - SN 1312,Chelsea Tech Fluorometer,Conductivity CTD 20 - SN 3868,Conductivity CTD 22-SN 3908,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Licor - LI-190SL Q46071,Oxygen CTD 20-SBE 43-SN 1794,Pressure CTD 20,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Teledyne Altimeter PA 500kHz,Temperature CTD 20 - SN 4722,Temperature CTD 21 - SN 6189,Temperature CTD 22-SN 2751,Transmissometer,Transmissometer - CTD 24 -CST-1421DR
When: 2015-06-04 13:04 to 2015-06-04 13:43 UTC
Where: 28° 49.7' S 154° 30.0' E
Maximum Depth (m): 507
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1042 | 7.2 | < 0.02 | < 0.02 | < 0.02 | 22.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1023 | 7.3 | < 0.02 | < 0.02 | < 0.02 | 22.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1022 | 8 | 220.09 | 35.658 | < 0.02 | 22.54 | 0.07 | < 0.02 | < 0.02 | 0.43 |
1024 | 8.3 | < 0.02 | < 0.02 | < 0.02 | 22.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1064 | 31.5 | < 0.02 | < 0.02 | < 0.02 | 22.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1066 | 31.7 | < 0.02 | < 0.02 | < 0.02 | 22.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1062 | 31.8 | 219.87 | 35.657 | < 0.02 | 22.54 | 0.06 | < 0.02 | < 0.02 | 0.43 |
1052 | 32 | < 0.02 | < 0.02 | < 0.02 | 22.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1016 | 56.3 | < 0.02 | < 0.02 | < 0.02 | 22.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1015 | 56.5 | < 0.02 | < 0.02 | < 0.02 | 22.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1059 | 56.7 | 212.14 | 35.655 | 0.77 | 22.23 | 0.13 | < 0.02 | 0.05 | 0.64 |
1055 | 56.9 | < 0.02 | < 0.02 | < 0.02 | 22.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1054 | 71.6 | < 0.02 | < 0.02 | < 0.02 | 20.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1010 | 71.6 | 189.45 | 35.654 | 3.30 | 20.66 | 0.34 | < 0.02 | 0.11 | 1.32 |
1071 | 71.9 | < 0.02 | < 0.02 | < 0.02 | 20.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1063 | 72.2 | < 0.02 | < 0.02 | < 0.02 | 20.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1006 | 106.5 | 169.98 | < 0.02 | 7.47 | 18.52 | 0.61 | 0.03 | 0.02 | 2.35 |
1007 | 106.5 | < 0.02 | < 0.02 | < 0.02 | 18.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1001 | 106.5 | < 0.02 | < 0.02 | < 0.02 | 18.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1008 | 107.2 | < 0.02 | < 0.02 | < 0.02 | 18.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1004 | 207.1 | 182.22 | < 0.02 | 9.87 | 15.62 | 0.76 | 0.06 | < 0.02 | 3.49 |
1057 | 307.9 | 183.60 | < 0.02 | 14.43 | 12.98 | 1.05 | 0.02 | < 0.02 | 5.93 |
1053 | 409.1 | 198.79 | < 0.02 | 17.30 | 10.84 | 1.21 | < 0.02 | < 0.02 | 7.04 |
1002 | 507 | 203.83 | < 0.02 | 21.10 | 8.90 | 1.45 | 0.04 | < 0.02 | 10.01 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Altimeter-163 | Benthos | 163 | Altitude(m) | |
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 20 - SN 3868 | Seabird | SBE4C | 3868 | |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Oxygen CTD 20-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
Teledyne Altimeter PA 500kHz | Teledyne | PA 500kHz | 228403 | Altitude(m) |
Temperature CTD 20 - SN 4722 | Sea-Bird Electronics Inc | SBE3T | 4722 | Temperature (deg C) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) | ||
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |