Deployment Details
Survey: - IN2015_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 6
Gear: Altimeter-163,Autosal Salinometer,CTD 20 - SN 0552,CTD 22,CTD 23 - SN 1312,Chelsea Tech Fluorometer,Conductivity CTD 20 - SN 3868,Conductivity CTD 22-SN 3908,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Licor - LI-190SL Q46071,Oxygen CTD 20-SBE 43-SN 1794,Pressure CTD 20,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Teledyne Altimeter PA 500kHz,Temperature CTD 20 - SN 4722,Temperature CTD 21 - SN 6189,Temperature CTD 22-SN 2751,Transmissometer,Transmissometer - CTD 24 -CST-1421DR
When: 2015-06-04 07:51 to 2015-06-04 08:28 UTC
Where: 28° 39.5' S 154° 20.2' E
Maximum Depth (m): 508.3
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1042 | 7.2 | < 0.02 | < 0.02 | 0.14 | 22.55 | 0.09 | 0.06 | 0.02 | 0.26 |
1022 | 7.5 | < 0.02 | < 0.02 | < 0.02 | 22.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1024 | 7.5 | 220.45 | 35.639 | < 0.02 | 22.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1023 | 7.7 | < 0.02 | < 0.02 | < 0.02 | 22.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1064 | 31.4 | < 0.02 | < 0.02 | 0.20 | 22.49 | 0.10 | 0.08 | 0.03 | 0.32 |
1052 | 31.4 | < 0.02 | < 0.02 | < 0.02 | 22.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1066 | 31.5 | 218.35 | 35.640 | < 0.02 | 22.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1062 | 31.8 | < 0.02 | < 0.02 | < 0.02 | 22.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1016 | 56.1 | 215.22 | 35.643 | < 0.02 | 22.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1055 | 56.4 | < 0.02 | < 0.02 | 1.59 | 22.47 | 0.21 | 0.09 | 0.07 | 0.66 |
1059 | 56.4 | < 0.02 | < 0.02 | < 0.02 | 22.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1015 | 56.5 | < 0.02 | < 0.02 | < 0.02 | 22.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1010 | 70.5 | < 0.02 | < 0.02 | < 0.02 | 20.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1054 | 70.6 | < 0.02 | < 0.02 | 6.78 | 20.60 | 0.58 | 0.09 | 0.05 | 1.89 |
1063 | 71 | 162.97 | 35.620 | < 0.02 | 20.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1071 | 71.7 | < 0.02 | < 0.02 | < 0.02 | 20.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1001 | 106.7 | < 0.02 | < 0.02 | 7.45 | 18.81 | 0.62 | 0.13 | 0.02 | 2.15 |
1008 | 106.8 | 167.70 | < 0.02 | < 0.02 | 18.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1006 | 107 | < 0.02 | < 0.02 | < 0.02 | 18.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1007 | 107.1 | < 0.02 | < 0.02 | < 0.02 | 18.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1004 | 205 | 188.47 | < 0.02 | 8.09 | 16.42 | 0.64 | 0.14 | < 0.02 | 2.47 |
1057 | 303.5 | 183.33 | 35.051 | 14.48 | 13.01 | 1.05 | 0.15 | < 0.02 | 5.75 |
1053 | 406.6 | 196.73 | < 0.02 | 18.56 | 10.45 | 1.29 | 0.11 | < 0.02 | 7.94 |
1002 | 508.3 | 203.43 | < 0.02 | 21.11 | 9.10 | 1.45 | 0.09 | < 0.02 | 9.67 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Altimeter-163 | Benthos | 163 | Altitude(m) | |
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 20 - SN 3868 | Seabird | SBE4C | 3868 | |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Oxygen CTD 20-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
Teledyne Altimeter PA 500kHz | Teledyne | PA 500kHz | 228403 | Altitude(m) |
Temperature CTD 20 - SN 4722 | Sea-Bird Electronics Inc | SBE3T | 4722 | Temperature (deg C) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) | ||
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |