Deployment Details
Survey: - IN2015_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 5
Gear: Altimeter-163,Autosal Salinometer,CTD 20 - SN 0552,CTD 22,CTD 23 - SN 1312,Chelsea Tech Fluorometer,Conductivity CTD 20 - SN 3868,Conductivity CTD 22-SN 3908,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Licor - LI-190SL Q46071,Oxygen CTD 20-SBE 43-SN 1794,Pressure CTD 20,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Teledyne Altimeter PA 500kHz,Temperature CTD 20 - SN 4722,Temperature CTD 21 - SN 6189,Temperature CTD 22-SN 2751,Transmissometer,Transmissometer - CTD 24 -CST-1421DR
When: 2015-06-03 20:24 to 2015-06-03 20:53 UTC
Where: 27° 43.0' S 153° 46.3' E
Maximum Depth (m): 111.4
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1024 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 22.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1042 | 5.8 | 216.52 | 35.639 | 0.04 | 22.85 | 0.09 | 0.06 | 0.02 | 0.53 |
1022 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 22.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1023 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 22.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1066 | 24.9 | < 0.02 | < 0.02 | < 0.02 | 22.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1062 | 25 | < 0.02 | < 0.02 | < 0.02 | 22.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1064 | 25.2 | 216.78 | 35.641 | 0.06 | 22.81 | 0.09 | 0.05 | < 0.02 | 0.54 |
1052 | 25.2 | < 0.02 | < 0.02 | < 0.02 | 22.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1016 | 48.6 | < 0.02 | < 0.02 | < 0.02 | 22.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1055 | 48.7 | 202.72 | 35.666 | 1.61 | 22.23 | 0.20 | 0.02 | 0.14 | 0.65 |
1015 | 48.9 | < 0.02 | < 0.02 | < 0.02 | 22.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1059 | 49.2 | < 0.02 | < 0.02 | < 0.02 | 22.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1063 | 77.1 | < 0.02 | < 0.02 | < 0.02 | 20.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1010 | 77.1 | < 0.02 | < 0.02 | < 0.02 | 20.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1054 | 77.6 | 201.56 | 35.624 | 2.97 | 20.79 | 0.28 | < 0.02 | 0.15 | 1.01 |
1071 | 77.6 | < 0.02 | < 0.02 | < 0.02 | 20.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1007 | 88.1 | < 0.02 | < 0.02 | < 0.02 | 20.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1006 | 88.2 | < 0.02 | < 0.02 | < 0.02 | 20.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1008 | 88.2 | < 0.02 | < 0.02 | < 0.02 | 20.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1001 | 88.4 | 197.80 | 35.604 | 3.58 | 20.22 | 0.33 | < 0.02 | 0.14 | 1.15 |
1004 | 110.7 | < 0.02 | < 0.02 | < 0.02 | 19.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1057 | 111 | < 0.02 | < 0.02 | < 0.02 | 19.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1002 | 111.2 | 192.76 | 35.607 | 4.44 | 19.57 | 0.39 | < 0.02 | 0.08 | 1.28 |
1053 | 111.4 | < 0.02 | < 0.02 | < 0.02 | 19.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Altimeter-163 | Benthos | 163 | Altitude(m) | |
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 20 - SN 3868 | Seabird | SBE4C | 3868 | |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Oxygen CTD 20-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
Teledyne Altimeter PA 500kHz | Teledyne | PA 500kHz | 228403 | Altitude(m) |
Temperature CTD 20 - SN 4722 | Sea-Bird Electronics Inc | SBE3T | 4722 | Temperature (deg C) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) | ||
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |