Please login if you have access to particular applications.
Deployment Details
Survey: - IN2015_V02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 4
Gear: Altitude CTD 20-41023,Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 3168,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-SBE 43-SN1239,Pressure CTD 20,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 20 - SN 4722,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2015-05-20 06:41 to 2015-05-20 10:29 UTC
Where: 27° 13.8' S 154° 28.0' E
Maximum Depth (m): 4844.7
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|
1024 | 8.2 | 213.97 | 35.527 | < 0.02 | 24.36 | 0.06 | 0.56 |
1023 | 24.6 | 213.70 | 35.526 | < 0.02 | 24.36 | 0.06 | 0.54 |
1022 | 41.3 | 213.08 | 35.526 | < 0.02 | 24.26 | 0.06 | 0.53 |
1042 | 63.7 | 213.12 | 35.640 | 0.41 | 23.28 | 0.08 | 0.51 |
1066 | 84.7 | 166.09 | 35.607 | 5.87 | 21.44 | 0.51 | 1.68 |
1052 | 125.2 | 197.62 | 35.638 | 3.55 | 19.51 | 0.36 | 1.01 |
1062 | 200.7 | 191.28 | 35.494 | 7.00 | 17.17 | 0.57 | 2.00 |
1064 | 251.3 | 194.01 | 35.408 | 8.41 | 16.01 | 0.66 | 2.56 |
1016 | 351.2 | 197.62 | 35.182 | 12.09 | 13.52 | 0.89 | 4.00 |
1015 | 475.4 | 200.35 | 34.910 | 16.83 | 11.13 | 1.19 | 6.16 |
1059 | 600.4 | 204.32 | 34.630 | 22.03 | 8.76 | 1.54 | 10.63 |
1055 | 800.1 | 199.37 | 34.449 | 27.91 | 6.23 | 1.96 | 25.32 |
1063 | 999.7 | 182.53 | 34.457 | 31.65 | 4.84 | 2.23 | 47.07 |
1071 | 1250.2 | 162.03 | 34.528 | 34.61 | 3.68 | 2.47 | 76.86 |
1010 | 1500.9 | 152.96 | 34.585 | 35.88 | 3.02 | 2.58 | 95.58 |
1054 | 1799.9 | 162.92 | 34.646 | 35.13 | 2.46 | 2.52 | 98.79 |
1061 | 2200.5 | < 0.02 | < 0.02 | < 0.02 | 2.07 | < 0.02 | < 0.02 |
1008 | 2200.7 | 179.85 | 34.700 | 33.53 | 2.07 | 2.40 | 97.33 |
1006 | 2500.2 | 187.31 | 34.718 | 33.08 | 1.84 | 2.37 | 101.47 |
1001 | 3000.4 | < 0.02 | 34.723 | 33.04 | 1.45 | 2.37 | 111.27 |
1004 | 3500.3 | < 0.02 | 34.719 | 33.24 | 1.23 | 2.39 | 117.70 |
1057 | 3998.9 | 200.66 | 34.716 | 33.35 | 1.18 | 2.40 | 120.16 |
1053 | 4498.9 | 200.62 | 34.715 | 33.43 | 1.20 | 2.40 | 121.35 |
1002 | 4844.7 | 200.80 | 34.716 | 33.52 | 1.24 | 2.41 | 121.71 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Altitude CTD 20-41023 | Teledyne | 916T | 41023 | Altitude(m) |
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3168 | Seabird | SBE-4 | 3168 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-SBE 43-SN1239 | Seabird | SBE 43 | 1239 | Oxygen (µM) |
Pressure CTD 20 | Digiquartz | 410K-134 | 552 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Temperature CTD 20 - SN 4722 | Sea-Bird Electronics Inc | SBE3T | 4722 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |