Please login if you have access to particular applications.
Deployment Details
Survey: - IN2014_E03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 20
Gear: Autosal Salinometer,CTD 22,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 22 - SN 4722
When: 2014-11-15 02:21 to 2014-11-15 03:03 UTC
Where: 42° 17.5' S 148° 58.6' E
Maximum Depth (m): 500.4
CTD data is not currently available.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
3111 | 4.7 | 274.79 | 35.466 | 2.06 | 14.73 | 0.26 | 0.05 | 0.34 | 1.20 |
2304 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 14.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1000 | 5 | < 0.02 | < 0.02 | < 0.02 | 14.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4709 | 5 | < 0.02 | < 0.02 | < 0.02 | 14.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2259 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 14.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1947 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 14.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1707 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 14.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8443 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 14.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4356 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 14.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2276 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 14.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4302 | 29.3 | < 0.02 | < 0.02 | < 0.02 | 14.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9233 | 29.5 | < 0.02 | < 0.02 | 2.06 | 14.51 | 0.26 | 0.08 | 0.37 | 1.19 |
9048 | 60.3 | < 0.02 | < 0.02 | 2.59 | 14.47 | 0.30 | 0.11 | 0.49 | 1.29 |
1848 | 60.5 | < 0.02 | < 0.02 | < 0.02 | 14.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9797 | 79.7 | < 0.02 | < 0.02 | < 0.02 | 14.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4388 | 79.8 | < 0.02 | < 0.02 | 3.79 | 14.33 | 0.36 | 0.02 | 0.45 | 1.56 |
1111 | 99.7 | < 0.02 | < 0.02 | < 0.02 | 14.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2580 | 100.5 | < 0.02 | < 0.02 | 4.33 | 14.25 | 0.39 | 0.31 | 0.22 | 1.76 |
2622 | 199.3 | < 0.02 | < 0.02 | 6.95 | 13.04 | 0.58 | 0.29 | 0.02 | 2.54 |
5948 | 200 | < 0.02 | < 0.02 | < 0.02 | 13.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4087 | 200.8 | < 0.02 | < 0.02 | < 0.02 | 13.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7112 | 251 | < 0.02 | < 0.02 | 6.89 | 12.80 | 0.56 | 0.05 | < 0.02 | 2.19 |
6028 | 251.2 | < 0.02 | < 0.02 | < 0.02 | 12.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2217 | 500.4 | 265.33 | 34.683 | 15.88 | 9.46 | 1.11 | 0.19 | < 0.02 | 4.63 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 22 | Seabird | Seabird SBE911 | 1243 | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 22 - SN 4722 | Sea-Bird Electronics Inc | SBE3T | 4722 | Temperature (deg C) |