Please login if you have access to particular applications.
Deployment Details
Survey: - SS2013_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 57
Operation No.: 57
Gear: CTD 21,Conductivity CTD 21 - SN 3309,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70371,Oxygen-CTD 21-SBE 43-SN 2125,Pressure CTD 21,Temperature CTD 21 - SN 5422,Transmissometer - CTD 22 -CST-1421DR
When: 2013-07-18 18:50 to 2013-07-18 21:03 UTC
Where:
29° 30.0' S
100° 00.0' E
to
29° 30.0' S
100° 00.0' E
Maximum Depth (m): 3994.9
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1052 | 4.8 | 233.80 | 35.820 | 0.07 | 19.06 | 0.09 | 0.03 | < 0.02 | 2.36 |
1062 | 31.3 | 0.07 | 19.07 | 0.10 | < 0.02 | < 0.02 | 2.36 | ||
1064 | 49 | 234.73 | 35.823 | 0.05 | 18.97 | 0.10 | 0.02 | < 0.02 | 2.33 |
1024 | 79.9 | 0.06 | 18.46 | 0.09 | 0.03 | < 0.02 | 2.14 | ||
1006 | 117.4 | 239.31 | 35.829 | 0.12 | 17.74 | 0.13 | 0.06 | < 0.02 | 1.76 |
1059 | 159.6 | 2.03 | 16.13 | 0.29 | 0.04 | < 0.02 | 1.89 | ||
1055 | 197 | 234.46 | 35.515 | 3.73 | 14.80 | 0.39 | 0.05 | < 0.02 | 1.89 |
1063 | 347.3 | 11.04 | 11.50 | 0.84 | < 0.02 | < 0.02 | 3.06 | ||
1071 | 497.9 | 248.41 | 34.770 | 15.08 | 10.06 | 1.08 | 0.03 | < 0.02 | 4.19 |
1010 | 694.4 | 236.04 | 34.609 | 20.10 | 8.76 | 1.38 | 0.03 | < 0.02 | 7.08 |
1054 | 896.5 | 200.27 | 34.410 | 29.70 | 5.75 | 2.07 | < 0.02 | < 0.02 | 26.89 |
1058 | 1100.9 | 171.94 | 34.445 | 34.11 | 4.13 | 2.46 | < 0.02 | < 0.02 | 56.07 |
1061 | 1295.1 | 150.08 | 34.538 | 35.42 | 3.65 | 2.58 | < 0.02 | < 0.02 | 76.18 |
1050 | 1497.6 | 35.53 | 3.19 | 2.59 | < 0.02 | < 0.02 | 86.55 | ||
1001 | 1999.8 | 160.17 | 34.704 | 34.68 | 2.48 | 2.52 | < 0.02 | < 0.02 | 105.64 |
1068 | 2497.3 | 33.94 | 2.01 | 2.47 | < 0.02 | < 0.02 | 113.46 | ||
1067 | 2996.5 | 187.95 | 34.727 | 33.46 | 1.61 | 2.42 | < 0.02 | < 0.02 | 118.48 |
103 | 3500.6 | 32.87 | 1.31 | 2.37 | < 0.02 | < 0.02 | 118.85 | ||
1060 | 3994.9 | 209.11 | 34.715 | 32.92 | 1.07 | 2.38 | 0.03 | < 0.02 | 123.48 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
Oxygen-CTD 21-SBE 43-SN 2125 | Seabird | SBE 43 | 2125 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) |
Temperature CTD 21 - SN 5422 | Seabird | SBE3plus | 5422 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |