Please login if you have access to particular applications.
Deployment Details
Survey: - SS2013_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 51
Operation No.: 51
Gear: CTD 21,Conductivity CTD 21 - SN 3309,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70371,Oxygen-CTD 21-SBE 43-SN 2125,Pressure CTD 21,Temperature CTD 21 - SN 5422,Transmissometer - CTD 22 -CST-1421DR
When: 2013-07-17 05:24 to 2013-07-17 08:09 UTC
Where:
26° 30.0' S
100° 00.0' E
to
26° 29.9' S
100° 00.0' E
Maximum Depth (m): 4693.8
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1052 | 6.2 | 229.27 | 35.557 | < 0.02 | 20.50 | 0.07 | < 0.02 | < 0.02 | 2.85 |
1062 | 19.8 | < 0.02 | 20.50 | 0.07 | < 0.02 | < 0.02 | 2.85 | ||
1064 | 39 | < 0.02 | 20.50 | 0.07 | < 0.02 | < 0.02 | 2.82 | ||
1024 | 81.8 | < 0.02 | 20.51 | 0.08 | < 0.02 | < 0.02 | 2.76 | ||
1006 | 99.1 | 225.92 | 35.683 | 0.03 | 20.39 | 0.07 | < 0.02 | < 0.02 | 2.71 |
1059 | 150.1 | 217.74 | 35.803 | 1.04 | 19.15 | 0.18 | < 0.02 | < 0.02 | 2.56 |
1055 | 169.5 | 1.26 | 18.65 | 0.20 | < 0.02 | < 0.02 | 2.45 | ||
1063 | 201.1 | 219.36 | 35.776 | 1.80 | 17.61 | 0.25 | < 0.02 | < 0.02 | 2.39 |
1071 | 299.2 | 4.85 | 14.37 | 0.46 | < 0.02 | < 0.02 | 2.00 | ||
1010 | 496.7 | 248.43 | 34.780 | 14.69 | 10.13 | 1.05 | < 0.02 | < 0.02 | 3.87 |
1054 | 701.7 | 231.08 | 34.570 | 21.42 | 8.42 | 1.44 | < 0.02 | < 0.02 | 8.15 |
1058 | 897.6 | 188.30 | 34.407 | 32.86 | 5.03 | 2.20 | < 0.02 | < 0.02 | 38.09 |
1061 | 1202.2 | 137.82 | 34.561 | 37.51 | 3.92 | 2.59 | < 0.02 | < 0.02 | 83.13 |
1050 | 1499.3 | 142.83 | 34.637 | 37.32 | 3.21 | 2.58 | < 0.02 | < 0.02 | 97.11 |
1001 | 1999.3 | 36.06 | 2.42 | 2.48 | < 0.02 | 0.04 | 110.53 | ||
1068 | 2600.1 | 177.84 | 34.726 | 35.17 | 1.89 | 2.43 | < 0.02 | 0.02 | 119.83 |
1067 | 3201.6 | 189.24 | 34.726 | 34.79 | 1.52 | 2.38 | < 0.02 | < 0.02 | 125.94 |
103 | 4197.1 | 34.26 | 1.09 | 2.34 | < 0.02 | < 0.02 | 129.21 | ||
1060 | 4693.8 | 210.93 | 34.711 | 34.20 | 1.04 | 2.34 | < 0.02 | < 0.02 | 130.50 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
Oxygen-CTD 21-SBE 43-SN 2125 | Seabird | SBE 43 | 2125 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) |
Temperature CTD 21 - SN 5422 | Seabird | SBE3plus | 5422 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |