Please login if you have access to particular applications.
Deployment Details
Survey: - SS2013_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 47
Operation No.: 47
Gear: CTD 21,Conductivity CTD 21 - SN 3309,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70371,Oxygen-CTD 21-SBE 43-SN 2125,Pressure CTD 21,Temperature CTD 21 - SN 5422,Transmissometer - CTD 22 -CST-1421DR
When: 2013-07-14 07:44 to 2013-07-14 10:45 UTC
Where:
25° 00.0' S
105° 00.0' E
to
25° 00.0' S
105° 00.0' E
Maximum Depth (m): 5048
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Nitrate (µM) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|
| 19 | 6.6 | 223.66 | < 0.02 | 0.04 | < 0.02 | < 0.02 | 3.01 |
| 18 | 29.3 | < 0.02 | 0.04 | < 0.02 | < 0.02 | 2.96 | |
| 17 | 64.3 | < 0.02 | 0.05 | < 0.02 | < 0.02 | 3.02 | |
| 16 | 98.8 | 222.09 | < 0.02 | 0.05 | 0.04 | < 0.02 | 2.98 |
| 15 | 129.8 | 0.63 | 0.10 | < 0.02 | 0.12 | 3.23 | |
| 14 | 160.2 | 197.99 | 2.23 | 0.23 | < 0.02 | 0.02 | 3.86 |
| 13 | 201.6 | 1.83 | 0.25 | < 0.02 | < 0.02 | 2.95 | |
| 12 | 230.2 | 208.68 | 2.31 | 0.28 | < 0.02 | < 0.02 | 2.87 |
| 11 | 500 | 244.31 | 15.67 | 1.11 | < 0.02 | < 0.02 | 4.22 |
| 10 | 800.9 | 188.26 | 30.38 | 2.08 | < 0.02 | < 0.02 | 30.41 |
| 9 | 1200.6 | 118.92 | 36.77 | 2.70 | < 0.02 | < 0.02 | 88.06 |
| 8 | 1601.2 | 36.42 | 2.64 | < 0.02 | < 0.02 | 101.02 | |
| 7 | 2000.6 | 150.78 | 35.75 | 2.58 | < 0.02 | < 0.02 | 114.28 |
| 6 | 2500.1 | 35.17 | 2.53 | < 0.02 | < 0.02 | 121.77 | |
| 5 | 3001.9 | 179.07 | 34.55 | 2.46 | < 0.02 | < 0.02 | 123.08 |
| 4 | 3498.1 | 34.16 | 2.44 | < 0.02 | < 0.02 | 125.26 | |
| 3 | 4000.6 | 196.97 | 34.00 | 2.41 | < 0.02 | < 0.02 | 127.12 |
| 1 | 5045 | 210.98 | 33.48 | 2.35 | < 0.02 | < 0.02 | 125.50 |
| 2 | 5048 | 210.89 | 33.50 | 2.36 | < 0.02 | < 0.02 | 125.32 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
| Conductivity CTD 21 - SN 3309 | Seabird | SBE4C | 3309 | |
| Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
| Licor - CTD 21 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
| Oxygen-CTD 21-SBE 43-SN 2125 | Seabird | SBE 43 | 2125 | Oxygen (µM) |
| Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) |
| Temperature CTD 21 - SN 5422 | Seabird | SBE3plus | 5422 | Temperature (deg C) |
| Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |