Please login if you have access to particular applications.
Deployment Details
Survey: - SS2013_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 44
Operation No.: 44
Gear: CTD 21,Conductivity CTD 21 - SN 3309,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70371,Oxygen-CTD 21-SBE 43-SN 2125,Pressure CTD 21,Temperature CTD 21 - SN 5422,Transmissometer - CTD 22 -CST-1421DR
When: 2013-07-13 15:45 to 2013-07-13 18:39 UTC
Where:
26° 00.0' S
105° 00.0' E
to
26° 00.0' S
105° 00.0' E
Maximum Depth (m): 5126.2
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1052 | 6.9 | 223.24 | 35.226 | < 0.02 | 21.66 | 0.05 | 0.03 | < 0.02 | 2.76 |
1062 | 50.3 | < 0.02 | 21.09 | 0.05 | 0.05 | < 0.02 | 2.77 | ||
1064 | 89.9 | 219.66 | 35.516 | 0.32 | 20.34 | 0.08 | 0.08 | 0.02 | 2.81 |
1024 | 110.3 | 0.02 | 19.84 | 0.05 | 0.05 | < 0.02 | 2.58 | ||
1006 | 139.4 | 230.69 | 35.719 | < 0.02 | 19.06 | 0.05 | 0.06 | < 0.02 | 2.41 |
1059 | 171.4 | 0.15 | 17.67 | 0.09 | 0.07 | 0.04 | 2.30 | ||
1055 | 209.7 | 214.35 | 35.769 | 2.21 | 14.91 | 0.23 | 0.07 | < 0.02 | 2.44 |
1063 | 350.4 | 7.62 | 11.04 | 0.59 | 0.07 | < 0.02 | 2.03 | ||
1071 | 501.3 | 250.54 | 34.791 | 13.88 | 9.60 | 0.97 | 0.06 | < 0.02 | 3.56 |
1010 | 939.8 | 176.98 | 34.429 | 33.10 | 4.42 | 2.33 | 0.04 | < 0.02 | 46.15 |
1054 | 1349.5 | 143.48 | 34.585 | 35.97 | 3.27 | 2.59 | 0.03 | < 0.02 | 84.65 |
1058 | 1801.1 | 35.12 | 2.54 | 2.52 | 0.03 | < 0.02 | 102.58 | ||
1061 | 2200.8 | 163.43 | 34.723 | 34.85 | 2.13 | 2.51 | 0.03 | < 0.02 | 115.68 |
1050 | 2600.9 | 34.25 | 1.85 | 2.45 | 0.03 | < 0.02 | 118.34 | ||
1001 | 3002.2 | 183.50 | 34.726 | 33.97 | 1.59 | 2.42 | 0.03 | < 0.02 | 121.48 |
1068 | 3500.3 | 33.79 | 1.34 | 2.40 | 0.03 | < 0.02 | 125.36 | ||
1067 | 4001.9 | 202.24 | 34.719 | 33.43 | 1.17 | 2.37 | 0.04 | < 0.02 | 125.48 |
103 | 4501.5 | 210.01 | 34.709 | 33.24 | 1.04 | 2.35 | 0.04 | < 0.02 | 125.40 |
1060 | 5126.2 | 210.87 | 34.708 | 33.17 | 1.09 | 2.35 | 0.04 | < 0.02 | 125.53 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
Oxygen-CTD 21-SBE 43-SN 2125 | Seabird | SBE 43 | 2125 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) |
Temperature CTD 21 - SN 5422 | Seabird | SBE3plus | 5422 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |