Please login if you have access to particular applications.
Deployment Details
Survey: - SS2013_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 43
Operation No.: 43
Gear: CTD 21,Conductivity CTD 21 - SN 3309,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70371,Oxygen-CTD 21-SBE 43-SN 2125,Pressure CTD 21,Temperature CTD 21 - SN 5422,Transmissometer - CTD 22 -CST-1421DR
When: 2013-07-13 11:50 to 2013-07-13 13:08 UTC
Where:
26° 15.0' S
105° 00.2' E
to
26° 15.0' S
105° 00.1' E
Maximum Depth (m): 2000.5
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1062 | 5.8 | 19.88 | |||||||
1064 | 5.8 | 231.42 | 35.683 | < 0.02 | 19.88 | 0.05 | 0.04 | < 0.02 | 2.58 |
1052 | 6 | 19.88 | |||||||
1024 | 39.7 | < 0.02 | 19.80 | 0.05 | 0.03 | < 0.02 | 2.49 | ||
1006 | 70.7 | 19.66 | |||||||
1059 | 80.6 | 231.00 | 35.768 | 0.04 | 19.52 | 0.06 | 0.04 | < 0.02 | 2.38 |
1055 | 94.3 | 19.21 | |||||||
1010 | 112.2 | 235.30 | 35.855 | < 0.02 | 18.98 | 0.06 | 0.03 | < 0.02 | 2.15 |
1071 | 112.8 | 18.98 | |||||||
1063 | 113.1 | 18.97 | |||||||
1054 | 150.2 | 230.97 | 35.871 | 0.22 | 18.69 | 0.09 | 0.04 | 0.04 | 1.98 |
1058 | 200.1 | 1.61 | 16.67 | 0.22 | 0.03 | < 0.02 | 1.81 | ||
1061 | 450.3 | 249.22 | 34.832 | 13.40 | 10.47 | 0.94 | 0.03 | < 0.02 | 3.49 |
1050 | 871 | 194.12 | 34.400 | 31.36 | 5.21 | 2.17 | 0.04 | < 0.02 | 33.75 |
1001 | 999 | 34.72 | 4.55 | 2.47 | 0.03 | < 0.02 | 60.82 | ||
1068 | 1180.1 | 138.92 | 34.555 | 36.06 | 3.93 | 2.60 | 0.03 | < 0.02 | 79.60 |
1067 | 1300.5 | 3.59 | |||||||
103 | 1602.6 | 148.34 | 34.654 | 35.63 | 2.95 | 2.57 | 0.04 | < 0.02 | 95.98 |
1060 | 2000.5 | 160.61 | 34.711 | 34.83 | 2.36 | 2.49 | 0.04 | < 0.02 | 109.56 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
Oxygen-CTD 21-SBE 43-SN 2125 | Seabird | SBE 43 | 2125 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) |
Temperature CTD 21 - SN 5422 | Seabird | SBE3plus | 5422 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |