Please login if you have access to particular applications.
Deployment Details
Survey: - SS2013_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 39
Operation No.: 39
Gear: CTD 21,Conductivity CTD 21 - SN 3309,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70371,Oxygen-CTD 21-SBE 43-SN 2125,Pressure CTD 21,Temperature CTD 21 - SN 5422,Transmissometer - CTD 22 -CST-1421DR
When: 2013-07-12 14:58 to 2013-07-12 16:19 UTC
Where:
27° 15.0' S
105° 00.0' E
to
27° 15.0' S
105° 00.0' E
Maximum Depth (m): 2004.6
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1052 | 5.4 | 20.13 | |||||||
1064 | 6.3 | 231.66 | 35.583 | 0.05 | 20.13 | < 0.02 | 0.02 | < 0.02 | 2.55 |
1062 | 6.4 | 20.14 | |||||||
1024 | 52.1 | 0.08 | 20.14 | 0.02 | < 0.02 | < 0.02 | 2.54 | ||
1006 | 75.2 | 230.73 | 35.620 | 0.09 | 20.01 | 0.03 | 0.04 | < 0.02 | 2.52 |
1063 | 98.8 | 19.96 | |||||||
1059 | 99.2 | 0.06 | 19.96 | < 0.02 | 0.05 | < 0.02 | 2.45 | ||
1055 | 99.3 | 19.96 | |||||||
1071 | 130.5 | 223.93 | 35.783 | 0.45 | 19.61 | 0.09 | 0.06 | 0.08 | 2.32 |
1010 | 173 | 18.48 | |||||||
1054 | 210.4 | 217.69 | 35.651 | 2.68 | 17.08 | 0.26 | 0.04 | < 0.02 | 2.03 |
1058 | 322.6 | 238.22 | 34.841 | 14.47 | 10.48 | 1.02 | 0.04 | < 0.02 | 4.54 |
1061 | 450.5 | 25.53 | 7.24 | 1.74 | 0.03 | < 0.02 | 15.81 | ||
1050 | 600.6 | 192.28 | 34.410 | 30.97 | 5.32 | 2.15 | 0.04 | < 0.02 | 33.72 |
1001 | 797 | 4.24 | |||||||
1068 | 1001.4 | 146.51 | 34.540 | 35.79 | 3.75 | 2.56 | 0.04 | < 0.02 | 77.21 |
1067 | 1200.5 | 3.45 | |||||||
103 | 1500.4 | 149.58 | 34.654 | 35.55 | 2.91 | 2.55 | 0.05 | < 0.02 | 96.15 |
1060 | 2004.6 | 161.22 | 34.716 | 34.81 | 2.26 | 2.49 | 0.05 | < 0.02 | 113.40 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
Oxygen-CTD 21-SBE 43-SN 2125 | Seabird | SBE 43 | 2125 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) |
Temperature CTD 21 - SN 5422 | Seabird | SBE3plus | 5422 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |