Deployment Details
Survey: - SS2013_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 37
Operation No.: 37
Gear: CTD 21,Conductivity CTD 21 - SN 3309,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70371,Oxygen-CTD 21-SBE 43-SN 2125,Pressure CTD 21,Temperature CTD 21 - SN 5422,Transmissometer - CTD 22 -CST-1421DR
When: 2013-07-12 04:23 to 2013-07-12 05:49 UTC
Where:
27° 44.8' S
105° 00.0' E
to
27° 44.6' S
104° 59.3' E
Maximum Depth (m): 2004.1
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1064 | 5.5 | 227.03 | 35.530 | 0.22 | 20.18 | 0.05 | 0.02 | < 0.02 | 2.79 |
1052 | 5.6 | 20.18 | |||||||
1062 | 5.7 | 20.18 | |||||||
1024 | 39.9 | 0.20 | 20.18 | 0.03 | < 0.02 | < 0.02 | 2.73 | ||
1006 | 64.6 | 227.34 | 35.726 | 0.10 | 19.94 | 0.03 | < 0.02 | < 0.02 | 2.42 |
1063 | 77.5 | 0.14 | 19.61 | 0.06 | 0.02 | 0.03 | 2.18 | ||
1059 | 78.7 | 19.64 | |||||||
1055 | 79.2 | 19.63 | |||||||
1071 | 127.5 | 227.03 | 35.820 | 0.63 | 18.30 | 0.11 | < 0.02 | 0.11 | 1.90 |
1010 | 174.3 | 2.74 | 16.18 | 0.25 | < 0.02 | < 0.02 | 1.86 | ||
1054 | 201.1 | 228.43 | 35.496 | 3.65 | 15.15 | 0.31 | 0.02 | < 0.02 | 1.74 |
1058 | 300.2 | 9.14 | 12.06 | 0.67 | 0.05 | < 0.02 | 2.14 | ||
1061 | 450.4 | 246.80 | 34.689 | 16.58 | 9.51 | 1.12 | < 0.02 | < 0.02 | 4.35 |
1050 | 600.9 | 8.34 | |||||||
1001 | 749.6 | 193.89 | 34.413 | 30.23 | 5.57 | 2.07 | < 0.02 | < 0.02 | 30.45 |
1068 | 851.9 | 4.82 | |||||||
1067 | 1099.9 | 136.70 | 34.557 | 35.55 | 4.07 | 2.57 | 0.06 | < 0.02 | 79.29 |
103 | 1501.9 | 3.03 | |||||||
1060 | 2004.1 | 159.43 | 34.711 | 34.48 | 2.37 | 2.46 | 0.07 | < 0.02 | 109.64 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
Oxygen-CTD 21-SBE 43-SN 2125 | Seabird | SBE 43 | 2125 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) |
Temperature CTD 21 - SN 5422 | Seabird | SBE3plus | 5422 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |