Deployment Details
Survey: - SS2013_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 35
Operation No.: 35
Gear: CTD 21,Conductivity CTD 21 - SN 3309,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70371,Oxygen-CTD 21-SBE 43-SN 2125,Pressure CTD 21,Temperature CTD 21 - SN 5422,Transmissometer - CTD 22 -CST-1421DR
When: 2013-07-11 14:55 to 2013-07-11 17:55 UTC
Where:
28° 30.0' S
105° 00.1' E
to
28° 29.9' S
104° 59.9' E
Maximum Depth (m): 5052.9
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1052 | 4.5 | 231.44 | 35.561 | 0.03 | 19.96 | 0.08 | 0.05 | < 0.02 | 2.76 |
1062 | 40.7 | 230.51 | 35.632 | 0.05 | 19.99 | 0.08 | 0.06 | < 0.02 | 2.69 |
1064 | 75.8 | 0.08 | 19.58 | 0.10 | 0.06 | < 0.02 | 2.44 | ||
1024 | 100.3 | 0.04 | 19.23 | 0.09 | 0.16 | < 0.02 | 2.27 | ||
1006 | 125 | 230.75 | 35.849 | 0.25 | 18.78 | 0.11 | 0.09 | 0.06 | 2.05 |
1059 | 159.7 | 222.44 | 35.751 | 1.63 | 17.24 | 0.25 | 0.08 | 0.02 | 2.05 |
1055 | 199.4 | 2.42 | 15.41 | 0.31 | 0.06 | < 0.02 | 1.62 | ||
1063 | 497.9 | 247.91 | 34.729 | 15.59 | 9.79 | 1.09 | 0.05 | < 0.02 | 4.16 |
1071 | 898.4 | 196.57 | 34.390 | 31.14 | 5.12 | 2.17 | 0.06 | < 0.02 | 33.38 |
1010 | 1200.9 | 145.32 | 34.535 | 35.44 | 3.89 | 2.57 | 0.05 | < 0.02 | 75.42 |
1054 | 1597.5 | 35.30 | 2.97 | 2.57 | 0.04 | < 0.02 | 94.25 | ||
1058 | 1800.6 | 157.09 | 34.687 | 34.84 | 2.67 | 2.52 | 0.05 | < 0.02 | 100.25 |
1061 | 2202.3 | 34.27 | 2.24 | 2.49 | 0.03 | < 0.02 | 110.29 | ||
1050 | 2600 | 176.42 | 34.726 | 33.78 | 1.92 | 2.44 | 0.03 | < 0.02 | 114.59 |
1001 | 3001.2 | 33.52 | 1.67 | 2.41 | 0.03 | < 0.02 | 117.82 | ||
1068 | 3502.3 | 197.10 | 34.722 | 33.16 | 1.36 | 2.38 | 0.04 | < 0.02 | 121.20 |
1067 | 4002 | 33.21 | 1.17 | 2.38 | 0.04 | < 0.02 | 125.59 | ||
103 | 4497.2 | 210.76 | 34.710 | 32.99 | 1.04 | 2.36 | 0.05 | < 0.02 | 124.59 |
1060 | 5052.9 | 212.24 | 32.99 | 1.05 | 2.34 | 0.03 | < 0.02 | 125.04 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
Oxygen-CTD 21-SBE 43-SN 2125 | Seabird | SBE 43 | 2125 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) |
Temperature CTD 21 - SN 5422 | Seabird | SBE3plus | 5422 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |