Please login if you have access to particular applications.
Deployment Details
Survey: - SS2013_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 34
Operation No.: 34
Gear: CTD 21,Conductivity CTD 21 - SN 3309,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70371,Oxygen-CTD 21-SBE 43-SN 2125,Pressure CTD 21,Temperature CTD 21 - SN 5422,Transmissometer - CTD 22 -CST-1421DR
When: 2013-07-11 07:08 to 2013-07-11 10:17 UTC
Where:
29° 00.0' S
105° 00.0' E
to
29° 00.0' S
105° 00.0' E
Maximum Depth (m): 5243.9
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1052 | 5 | 235.91 | 35.813 | < 0.02 | 18.88 | 0.06 | 0.03 | < 0.02 | 2.55 |
1062 | 19.9 | < 0.02 | 18.89 | 0.06 | 0.04 | < 0.02 | 2.56 | ||
1064 | 39.4 | < 0.02 | 18.87 | 0.07 | 0.03 | < 0.02 | 2.54 | ||
1024 | 68.5 | 235.54 | 35.837 | < 0.02 | 18.86 | 0.07 | 0.04 | < 0.02 | 2.40 |
1006 | 88.9 | 234.05 | 35.794 | 0.11 | 17.94 | 0.13 | 0.04 | 0.04 | 1.99 |
1059 | 125.1 | 226.94 | 35.719 | 1.60 | 16.73 | 0.24 | 0.04 | 0.03 | 2.09 |
1055 | 247.6 | 235.78 | 35.303 | 6.30 | 13.40 | 0.55 | 0.04 | < 0.02 | 2.22 |
1063 | 500 | 247.23 | 34.722 | 15.61 | 9.74 | 1.12 | 0.05 | < 0.02 | 4.29 |
1071 | 848 | 201.20 | 34.417 | 28.91 | 6.06 | 2.01 | 0.04 | < 0.02 | 23.81 |
1010 | 1346.9 | 146.57 | 34.583 | 35.69 | 3.38 | 2.58 | 0.04 | < 0.02 | 85.72 |
1054 | 1566 | 35.40 | 2.99 | 2.56 | 0.05 | < 0.02 | 94.38 | ||
1058 | 1999.7 | 34.58 | 2.37 | 2.49 | 0.04 | < 0.02 | 109.51 | ||
1061 | 2296.7 | 169.41 | 34.724 | 34.26 | 2.08 | 2.46 | 0.03 | < 0.02 | 115.81 |
1050 | 2800.7 | 33.88 | 1.74 | 2.43 | 0.05 | < 0.02 | 120.89 | ||
1001 | 3301.7 | 191.02 | 34.724 | 33.47 | 1.48 | 2.39 | 0.04 | < 0.02 | 122.68 |
1068 | 3801.7 | 33.45 | 1.28 | 2.39 | 0.04 | < 0.02 | 122.98 | ||
1067 | 4296.9 | 205.58 | 34.713 | 33.20 | 1.13 | 2.35 | 0.04 | < 0.02 | 127.25 |
103 | 4799.3 | 33.06 | 1.05 | 2.36 | 0.04 | < 0.02 | 127.49 | ||
1060 | 5243.9 | 212.28 | 34.707 | 32.99 | 1.08 | 2.34 | 0.06 | < 0.02 | 126.87 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
Oxygen-CTD 21-SBE 43-SN 2125 | Seabird | SBE 43 | 2125 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) |
Temperature CTD 21 - SN 5422 | Seabird | SBE3plus | 5422 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |