Deployment Details
Survey: - SS2013_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 29
Operation No.: 29
Gear: CTD 21,Conductivity CTD 21 - SN 3309,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70371,Oxygen-CTD 21-SBE 43-SN 2125,Pressure CTD 21,Temperature CTD 21 - SN 5422,Transmissometer - CTD 22 -CST-1421DR
When: 2013-07-09 19:42 to 2013-07-09 23:13 UTC
Where:
31° 05.2' S
105° 27.5' E
to
31° 05.3' S
105° 27.7' E
Maximum Depth (m): 5266.6
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1052 | 6 | 239.44 | 35.872 | 0.03 | 18.14 | 0.07 | 0.15 | < 0.02 | 2.09 |
1062 | 19.8 | < 0.02 | 18.14 | 0.07 | 0.08 | < 0.02 | 2.07 | ||
1064 | 40.9 | < 0.02 | 18.14 | 0.08 | 0.13 | < 0.02 | 2.08 | ||
1024 | 79.9 | 239.03 | 35.863 | 0.03 | 18.09 | 0.07 | 0.16 | < 0.02 | 2.05 |
1006 | 119.7 | 0.11 | 17.94 | 0.09 | 0.10 | 0.04 | 1.93 | ||
1059 | 141.1 | 0.86 | 16.34 | 0.19 | 0.06 | 0.11 | 1.63 | ||
1055 | 201.1 | 238.38 | 35.378 | 4.96 | 13.87 | 0.45 | 0.04 | < 0.02 | 1.84 |
1063 | 375.4 | 255.31 | 34.841 | 12.50 | 10.55 | 0.91 | 0.03 | < 0.02 | 3.22 |
1071 | 598.4 | 19.26 | 8.94 | 1.32 | 0.04 | < 0.02 | 5.91 | ||
1010 | 901.4 | 201.13 | 34.382 | 31.09 | 5.24 | 2.14 | 0.07 | < 0.02 | 30.57 |
1054 | 1104.6 | 181.85 | 34.422 | 34.21 | 3.88 | 2.41 | 0.09 | < 0.02 | 53.69 |
1058 | 1399.8 | 153.12 | 34.576 | 35.87 | 3.23 | 2.58 | 0.12 | < 0.02 | 82.50 |
1061 | 1798.9 | 2.63 | |||||||
1050 | 2400 | 34.43 | 2.05 | 2.46 | 0.08 | < 0.02 | 112.61 | ||
1001 | 3001.1 | 186.57 | 34.729 | 33.78 | 1.65 | 2.40 | 0.17 | < 0.02 | 118.00 |
1068 | 3802.4 | 201.02 | 34.719 | 33.51 | 1.25 | 2.38 | 0.06 | < 0.02 | 123.65 |
1067 | 4301.2 | 33.45 | 1.14 | 2.37 | < 0.02 | < 0.02 | 125.60 | ||
103 | 4797.2 | 210.85 | 34.709 | 33.33 | 1.05 | 2.37 | < 0.02 | < 0.02 | 125.65 |
1060 | 5266.6 | 212.32 | 34.707 | 33.33 | 1.06 | 2.37 | < 0.02 | < 0.02 | 125.82 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
Oxygen-CTD 21-SBE 43-SN 2125 | Seabird | SBE 43 | 2125 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) |
Temperature CTD 21 - SN 5422 | Seabird | SBE3plus | 5422 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |