Please login if you have access to particular applications.
Deployment Details
Survey: - SS2013_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 24
Operation No.: 24
Gear: CTD 21,Conductivity CTD 21 - SN 3309,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70371,Oxygen-CTD 21-SBE 43-SN 2125,Pressure CTD 21,Temperature CTD 21 - SN 5422,Transmissometer - CTD 22 -CST-1421DR
When: 2013-07-08 10:51 to 2013-07-08 14:17 UTC
Where:
31° 25.9' S
108° 24.1' E
to
31° 25.8' S
108° 24.0' E
Maximum Depth (m): 5426.8
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1052 | 6.9 | 237.94 | 35.744 | < 0.02 | 18.45 | 0.07 | < 0.02 | < 0.02 | 2.23 |
1062 | 22.7 | < 0.02 | 18.38 | 0.07 | < 0.02 | < 0.02 | 2.16 | ||
1064 | 40 | < 0.02 | 18.37 | 0.07 | < 0.02 | < 0.02 | 2.18 | ||
1024 | 59.8 | 237.75 | 35.780 | 0.02 | 18.27 | 0.07 | < 0.02 | < 0.02 | 2.07 |
1006 | 90.3 | 240.56 | 35.759 | 0.05 | 17.61 | 0.08 | < 0.02 | < 0.02 | 1.91 |
1059 | 149.6 | 2.05 | 15.56 | 0.29 | < 0.02 | < 0.02 | 1.59 | ||
1055 | 199.2 | 236.27 | 35.409 | 3.89 | 14.36 | 0.39 | < 0.02 | < 0.02 | 1.64 |
1063 | 450.4 | 252.74 | 34.741 | 14.82 | 9.90 | 1.04 | < 0.02 | < 0.02 | 3.91 |
1071 | 900.4 | 196.31 | 34.385 | 31.34 | 4.96 | 2.18 | < 0.02 | < 0.02 | 34.66 |
1010 | 1200.4 | 34.95 | 3.53 | 2.51 | < 0.02 | < 0.02 | 69.76 | ||
1054 | 1500.5 | 151.06 | 34.606 | 35.29 | 3.10 | 2.54 | < 0.02 | < 0.02 | 87.34 |
1058 | 1799.3 | 161.85 | 34.673 | 34.42 | 2.62 | 2.47 | < 0.02 | < 0.02 | 94.73 |
1061 | 2299.4 | 33.89 | 2.14 | 2.42 | < 0.02 | < 0.02 | 110.27 | ||
1050 | 2798.8 | 184.01 | 34.731 | 33.25 | 1.81 | 2.36 | < 0.02 | < 0.02 | 113.39 |
1001 | 3301.7 | 33.05 | 1.50 | 2.35 | < 0.02 | < 0.02 | 118.43 | ||
1068 | 3799.8 | 199.56 | 34.721 | 33.18 | 1.28 | 2.35 | < 0.02 | < 0.02 | 123.48 |
1067 | 4300 | 33.09 | 1.17 | 2.34 | < 0.02 | < 0.02 | 125.66 | ||
103 | 4801.8 | 210.83 | 34.709 | 32.95 | 1.06 | 2.33 | 0.02 | < 0.02 | 125.28 |
1060 | 5426.8 | 212.59 | 33.00 | 1.07 | 2.33 | 0.04 | < 0.02 | 126.40 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
Oxygen-CTD 21-SBE 43-SN 2125 | Seabird | SBE 43 | 2125 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) |
Temperature CTD 21 - SN 5422 | Seabird | SBE3plus | 5422 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |