Deployment Details
Survey: - SS2013_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 19
Operation No.: 19
Gear: CTD 21,Conductivity CTD 21 - SN 3309,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70371,Oxygen-CTD 21-SBE 43-SN 2125,Pressure CTD 21,Temperature CTD 21 - SN 5422,Transmissometer - CTD 22 -CST-1421DR
When: 2013-07-07 03:35 to 2013-07-07 06:38 UTC
Where:
31° 55.7' S
111° 12.5' E
to
31° 55.6' S
111° 12.5' E
Maximum Depth (m): 5125.1
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1052 | 7.7 | 226.11 | 35.239 | < 0.02 | 20.97 | 0.04 | 0.16 | < 0.02 | 2.61 |
1062 | 19.4 | < 0.02 | 20.96 | 0.04 | 0.08 | < 0.02 | 2.60 | ||
1064 | 40 | 0.02 | 20.74 | 0.04 | 0.07 | < 0.02 | 2.61 | ||
1024 | 66.8 | 228.17 | 35.524 | < 0.02 | 20.31 | 0.08 | 0.12 | < 0.02 | 2.51 |
1006 | 100.3 | 0.19 | 19.52 | 0.07 | 0.16 | 0.10 | 2.41 | ||
1059 | 140.7 | 225.49 | 35.747 | 0.78 | 18.58 | 0.12 | 0.10 | 0.05 | 2.19 |
1055 | 199.3 | 2.13 | 15.69 | 0.24 | 0.11 | < 0.02 | 1.77 | ||
1063 | 398.4 | 248.04 | 34.847 | 12.67 | 10.60 | 0.95 | 0.11 | < 0.02 | 3.21 |
1071 | 601.5 | 242.16 | 34.619 | 18.81 | 8.93 | 1.30 | 0.11 | < 0.02 | 5.85 |
1010 | 899.2 | 196.39 | 34.387 | 31.50 | 4.93 | 2.19 | 0.09 | < 0.02 | 35.43 |
1054 | 1299.4 | 151.06 | 34.551 | 35.99 | 3.45 | 2.57 | 0.10 | < 0.02 | 80.01 |
1058 | 1498.2 | 152.89 | 34.607 | 35.77 | 3.06 | 2.55 | 0.08 | < 0.02 | 86.87 |
1061 | 1998.7 | 163.44 | 34.707 | 34.74 | 2.40 | 2.49 | 0.07 | < 0.02 | 105.68 |
1050 | 2500.8 | 34.22 | 1.99 | 2.44 | 0.06 | < 0.02 | 113.90 | ||
1001 | 2997.4 | 184.27 | 34.727 | 33.85 | 1.67 | 2.39 | 0.06 | < 0.02 | 118.52 |
1068 | 3500.5 | 1.42 | |||||||
1067 | 3999.7 | 198.14 | 34.719 | 33.82 | 1.25 | 2.38 | 0.09 | < 0.02 | 127.46 |
103 | 4499.2 | 34.11 | 1.17 | 2.39 | 0.15 | < 0.02 | 127.86 | ||
1060 | 5125.1 | 211.34 | 34.708 | 33.39 | 1.06 | 2.35 | 0.12 | < 0.02 | 126.89 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
Oxygen-CTD 21-SBE 43-SN 2125 | Seabird | SBE 43 | 2125 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) |
Temperature CTD 21 - SN 5422 | Seabird | SBE3plus | 5422 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |