Deployment Details
Survey: - SS2013_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 18
Operation No.: 18
Gear: CTD 21,Conductivity CTD 21 - SN 3309,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70371,Oxygen-CTD 21-SBE 43-SN 2125,Pressure CTD 21,Temperature CTD 21 - SN 5422,Transmissometer - CTD 22 -CST-1421DR
When: 2013-07-06 21:27 to 2013-07-07 00:25 UTC
Where:
32° 02.4' S
111° 45.7' E
to
32° 02.4' S
111° 45.7' E
Maximum Depth (m): 5092
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1052 | 3.9 | 234.92 | 35.634 | < 0.02 | 18.80 | < 0.02 | 0.09 | < 0.02 | 2.18 |
1062 | 21.2 | 0.05 | 18.80 | 0.05 | 0.07 | < 0.02 | 2.14 | ||
1064 | 42.6 | 234.81 | 35.655 | 0.04 | 18.73 | 0.04 | 0.09 | < 0.02 | 2.14 |
1024 | 64.6 | 0.03 | 18.71 | 0.02 | 0.15 | < 0.02 | 2.14 | ||
1006 | 79.7 | 0.04 | 18.58 | 0.04 | 0.15 | < 0.02 | 2.08 | ||
1059 | 139.4 | 232.48 | 35.584 | 1.29 | 16.59 | 0.18 | 0.12 | < 0.02 | 1.59 |
1055 | 199.4 | 237.29 | 35.349 | 4.21 | 14.11 | 0.40 | 0.05 | < 0.02 | 1.58 |
1063 | 400.4 | 248.75 | 34.785 | 14.24 | 10.16 | 1.01 | 0.06 | < 0.02 | 3.38 |
1071 | 600.9 | 19.73 | 8.81 | 1.35 | 0.04 | < 0.02 | 5.91 | ||
1010 | 899.5 | 196.01 | 34.388 | 31.80 | 4.97 | 2.22 | 0.05 | < 0.02 | 34.87 |
1054 | 1198.3 | 158.89 | 34.496 | 35.10 | 3.77 | 2.53 | 0.13 | < 0.02 | 68.49 |
1058 | 1600 | 159.73 | 34.609 | 35.11 | 2.89 | 2.53 | 0.14 | < 0.02 | 84.17 |
1061 | 1998.1 | 34.40 | 2.43 | 2.49 | 0.05 | < 0.02 | 102.37 | ||
1050 | 2501.3 | 172.71 | 34.725 | 34.16 | 2.02 | 2.48 | 0.05 | < 0.02 | 115.55 |
1001 | 3001.8 | 33.75 | 1.73 | 2.44 | 0.20 | < 0.02 | 118.64 | ||
1068 | 3802.6 | 183.20 | 34.727 | 33.97 | 1.36 | 2.43 | 0.20 | < 0.02 | 119.28 |
1067 | 4398.3 | 33.56 | 1.23 | 2.39 | 0.15 | < 0.02 | 129.40 | ||
103 | 4795.7 | 205.17 | 34.712 | 33.46 | 1.15 | 2.40 | 0.11 | < 0.02 | 127.35 |
1060 | 5092 | 210.03 | 34.710 | 33.33 | 1.09 | 2.37 | 0.08 | < 0.02 | 127.30 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
Oxygen-CTD 21-SBE 43-SN 2125 | Seabird | SBE 43 | 2125 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) |
Temperature CTD 21 - SN 5422 | Seabird | SBE3plus | 5422 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |