Please login if you have access to particular applications.
Deployment Details
Survey: - SS2013_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 13
Operation No.: 13
Gear: CTD 21,Conductivity CTD 21 - SN 3309,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70371,Oxygen-CTD 21-SBE 43-SN 2125,Pressure CTD 21,Temperature CTD 21 - SN 5422,Transmissometer - CTD 22 -CST-1421DR
When: 2013-07-05 18:57 to 2013-07-05 20:54 UTC
Where:
32° 30.3' S
114° 03.2' E
to
32° 30.4' S
114° 02.7' E
Maximum Depth (m): 3590.3
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1062 | 5.9 | < 0.02 | 19.45 | 0.04 | 0.15 | < 0.02 | 2.08 | ||
1052 | 5.9 | 231.86 | 35.575 | < 0.02 | 19.46 | 0.05 | 0.22 | < 0.02 | 2.08 |
1064 | 21.1 | 231.84 | 35.574 | < 0.02 | 19.45 | 0.04 | 0.12 | < 0.02 | 2.07 |
1024 | 38.7 | < 0.02 | 19.45 | 0.04 | 0.18 | < 0.02 | 2.14 | ||
1006 | 76 | 231.55 | 35.584 | < 0.02 | 19.45 | 0.04 | 0.15 | < 0.02 | 2.14 |
1059 | 101 | 0.74 | 19.15 | 0.10 | 0.19 | 0.08 | 2.24 | ||
1055 | 150.7 | 0.30 | 18.54 | 0.06 | 0.14 | 0.12 | 1.92 | ||
1063 | 201.2 | 230.77 | 35.622 | 1.22 | 16.81 | 0.19 | 0.18 | < 0.02 | 1.64 |
1071 | 301.1 | 4.18 | 14.11 | 0.41 | 0.12 | < 0.02 | 1.55 | ||
1010 | 401.3 | 248.54 | 34.932 | 10.32 | 11.24 | 0.82 | 0.15 | < 0.02 | 2.30 |
1054 | 501 | 16.46 | 9.44 | 1.18 | 0.17 | < 0.02 | 4.41 | ||
1058 | 700.4 | 204.03 | 34.430 | 28.25 | 6.29 | 1.93 | 0.19 | < 0.02 | 22.43 |
1061 | 900.6 | 33.34 | 4.42 | 2.34 | 0.23 | < 0.02 | 49.69 | ||
1050 | 1100.3 | 176.43 | 34.458 | 34.71 | 3.41 | 2.45 | 0.20 | < 0.02 | 61.77 |
1001 | 1500.6 | 161.79 | 34.614 | 35.17 | 2.79 | 2.49 | 0.19 | < 0.02 | 84.86 |
1068 | 1999.6 | 167.69 | 34.708 | 34.25 | 2.34 | 2.47 | 0.25 | < 0.02 | 104.26 |
1067 | 2749.4 | 182.49 | 34.727 | 33.64 | 1.74 | 2.39 | 0.24 | < 0.02 | 117.94 |
103 | 3400.1 | 192.34 | 34.721 | 33.64 | 1.37 | 2.38 | 0.23 | < 0.02 | 126.12 |
1060 | 3590.3 | 194.07 | 34.718 | 33.64 | 1.30 | 2.38 | 0.19 | < 0.02 | 128.06 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
Oxygen-CTD 21-SBE 43-SN 2125 | Seabird | SBE 43 | 2125 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) |
Temperature CTD 21 - SN 5422 | Seabird | SBE3plus | 5422 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |