Please login if you have access to particular applications.
Deployment Details
Survey: - SS2013_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 12
Operation No.: 12
Gear: CTD 21,Conductivity CTD 21 - SN 3309,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70371,Oxygen-CTD 21-SBE 43-SN 2125,Pressure CTD 21,Temperature CTD 21 - SN 5422,Transmissometer - CTD 22 -CST-1421DR
When: 2013-07-05 15:37 to 2013-07-05 17:40 UTC
Where:
32° 31.3' S
114° 08.8' E
to
32° 31.2' S
114° 08.6' E
Maximum Depth (m): 2959.9
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1052 | 5.8 | 231.66 | 35.567 | < 0.02 | 19.52 | 0.04 | < 0.02 | < 0.02 | 1.97 |
1062 | 20.7 | < 0.02 | 19.52 | 0.05 | 0.02 | < 0.02 | 1.97 | ||
1064 | 40.3 | < 0.02 | 19.53 | 0.05 | 0.06 | < 0.02 | 2.00 | ||
1024 | 74.9 | 231.50 | 35.578 | < 0.02 | 19.51 | 0.05 | 0.18 | < 0.02 | 2.01 |
1006 | 105.7 | 232.80 | 35.667 | < 0.02 | 18.95 | 0.05 | 0.13 | < 0.02 | 2.08 |
1059 | 140.5 | 232.65 | 35.691 | 0.09 | 18.77 | 0.05 | 0.24 | 0.06 | 2.02 |
1055 | 182.8 | 0.76 | 17.87 | 0.12 | 0.17 | 0.05 | 1.66 | ||
1063 | 200.3 | 228.64 | 35.671 | 1.15 | 17.31 | 0.19 | 0.16 | 0.03 | 1.71 |
1071 | 350.8 | 4.96 | 13.72 | 0.45 | 0.18 | < 0.02 | 1.54 | ||
1010 | 528.8 | 243.19 | 34.695 | 16.73 | 9.37 | 1.19 | 0.18 | < 0.02 | 5.16 |
1054 | 749.1 | 190.78 | 34.399 | 32.25 | 4.67 | 2.26 | 0.21 | < 0.02 | 40.62 |
1058 | 1000.9 | 34.23 | 3.58 | 2.46 | 0.19 | < 0.02 | 57.82 | ||
1061 | 1250.4 | 35.15 | 3.10 | 2.52 | 0.14 | < 0.02 | 74.23 | ||
1050 | 1499.8 | 162.14 | 34.627 | 35.15 | 2.86 | 2.54 | 0.16 | < 0.02 | 88.48 |
1001 | 1749.8 | 34.38 | 2.53 | 2.51 | 0.19 | < 0.02 | 96.76 | ||
1068 | 2001.4 | 168.04 | 34.712 | 33.92 | 2.28 | 2.47 | 0.09 | < 0.02 | 106.11 |
1067 | 2501.4 | 177.24 | 34.727 | 33.62 | 1.90 | 2.44 | 0.15 | < 0.02 | 115.24 |
103 | 2802 | 183.37 | 34.728 | 33.31 | 1.73 | 2.41 | 0.15 | < 0.02 | 117.34 |
1060 | 2959.9 | 185.75 | 34.727 | 33.46 | 1.64 | 2.40 | 0.15 | < 0.02 | 120.63 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
Oxygen-CTD 21-SBE 43-SN 2125 | Seabird | SBE 43 | 2125 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) |
Temperature CTD 21 - SN 5422 | Seabird | SBE3plus | 5422 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |