Deployment Details
Survey: - SS2013_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 11
Operation No.: 11
Gear: CTD 21,Conductivity CTD 21 - SN 3309,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70371,Oxygen-CTD 21-SBE 43-SN 2125,Pressure CTD 21,Temperature CTD 21 - SN 5422,Transmissometer - CTD 22 -CST-1421DR
When: 2013-07-05 11:00 to 2013-07-05 12:48 UTC
Where:
32° 31.9' S
114° 12.2' E
to
32° 32.0' S
114° 12.2' E
Maximum Depth (m): 2503
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1052 | 5.8 | 232.29 | 35.560 | < 0.02 | 19.44 | 0.06 | 0.05 | < 0.02 | 2.02 |
1062 | 22.7 | < 0.02 | 19.44 | 0.05 | 0.07 | < 0.02 | 2.01 | ||
1064 | 44.5 | 231.53 | 35.591 | < 0.02 | 19.50 | 0.06 | 0.13 | < 0.02 | 1.97 |
1024 | 86.1 | 0.58 | 19.30 | 0.10 | 0.25 | 0.09 | 2.16 | ||
1006 | 121 | 227.06 | 35.756 | 0.47 | 18.87 | 0.09 | 0.16 | 0.12 | 1.96 |
1059 | 151.7 | 230.37 | 35.753 | 0.36 | 18.50 | 0.09 | 0.15 | 0.11 | 1.79 |
1055 | 172 | 229.78 | 35.704 | 0.65 | 18.01 | 0.12 | 0.09 | 0.07 | 1.67 |
1063 | 201.2 | 1.16 | 17.15 | 0.19 | 0.14 | 0.03 | 1.59 | ||
1071 | 500.1 | 244.34 | 34.822 | 13.50 | 10.40 | 1.01 | 0.07 | < 0.02 | 3.81 |
1010 | 751.4 | 198.10 | 34.374 | 31.90 | 4.53 | 2.26 | 0.06 | < 0.02 | 37.46 |
1054 | 1000.3 | 34.41 | 3.46 | 2.46 | 0.08 | < 0.02 | 59.03 | ||
1058 | 1202.1 | 35.20 | 3.20 | 2.54 | 0.06 | < 0.02 | 73.06 | ||
1061 | 1399.3 | 155.61 | 34.600 | 35.29 | 3.02 | 2.55 | 0.08 | < 0.02 | 84.83 |
1050 | 1600.3 | 34.80 | 2.71 | 2.52 | 0.15 | < 0.02 | 88.21 | ||
1001 | 1801.6 | 164.77 | 34.687 | 34.39 | 2.52 | 2.48 | 0.07 | < 0.02 | 96.88 |
1068 | 2002.3 | 167.39 | 34.712 | 34.15 | 2.29 | 2.48 | 0.08 | < 0.02 | 105.30 |
1067 | 2200.1 | 33.88 | 2.11 | 2.45 | 0.08 | < 0.02 | 110.19 | ||
103 | 2399.6 | 174.28 | 34.729 | 33.87 | 2.00 | 2.46 | 0.06 | < 0.02 | 113.32 |
1060 | 2503 | 176.45 | 34.727 | 33.81 | 1.94 | 2.46 | 0.06 | < 0.02 | 114.47 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
Oxygen-CTD 21-SBE 43-SN 2125 | Seabird | SBE 43 | 2125 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) |
Temperature CTD 21 - SN 5422 | Seabird | SBE3plus | 5422 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |