Please login if you have access to particular applications.
Deployment Details
Survey: - SS2013_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 10
Operation No.: 10
Gear: CTD 21,Conductivity CTD 21 - SN 3309,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70371,Oxygen-CTD 21-SBE 43-SN 2125,Pressure CTD 21,Temperature CTD 21 - SN 5422,Transmissometer - CTD 22 -CST-1421DR
When: 2013-07-05 08:01 to 2013-07-05 09:45 UTC
Where:
32° 33.5' S
114° 20.2' E
to
32° 33.6' S
114° 20.2' E
Maximum Depth (m): 2418.6
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1052 | 6 | 229.84 | 35.370 | < 0.02 | 20.21 | 0.06 | 0.05 | < 0.02 | 2.04 |
1062 | 31.2 | < 0.02 | 19.95 | 0.05 | 0.11 | < 0.02 | 2.05 | ||
1064 | 48.4 | < 0.02 | 19.61 | 0.06 | 0.13 | < 0.02 | 2.15 | ||
1024 | 72.9 | 230.46 | 35.645 | < 0.02 | 19.54 | 0.07 | 0.14 | < 0.02 | 2.15 |
1006 | 97.2 | 221.71 | 35.694 | 0.71 | 19.32 | 0.12 | 0.13 | 0.08 | 2.34 |
1059 | 129.6 | 220.48 | 35.740 | 0.94 | 19.05 | 0.13 | 0.06 | 0.06 | 2.26 |
1055 | 137.9 | 35.765 | 0.41 | 18.88 | 0.12 | 0.08 | 0.14 | 1.95 | |
1063 | 199.5 | 0.93 | 17.43 | 0.16 | 0.05 | 0.03 | 1.67 | ||
1071 | 300.7 | 3.60 | 14.45 | 0.38 | 0.04 | < 0.02 | 1.48 | ||
1010 | 502.3 | 34.726 | 15.51 | 9.72 | 1.15 | 0.03 | < 0.02 | 4.05 | |
1054 | 749.8 | 199.55 | 34.378 | 31.14 | 4.96 | 2.21 | 0.04 | < 0.02 | 32.88 |
1058 | 901.7 | 33.46 | 3.82 | 2.40 | 0.06 | < 0.02 | 49.69 | ||
1061 | 1000.8 | 169.60 | 34.466 | 34.67 | 3.65 | 2.50 | 0.04 | < 0.02 | 62.82 |
1050 | 1299.9 | 152.85 | 34.576 | 35.44 | 3.21 | 2.60 | 0.05 | < 0.02 | 82.90 |
1001 | 1501.4 | 35.14 | 2.91 | 2.58 | 0.03 | < 0.02 | 88.06 | ||
1068 | 1698 | 34.81 | 2.65 | 2.54 | < 0.02 | < 0.02 | 94.27 | ||
1067 | 1902 | 165.32 | 34.698 | 34.30 | 2.42 | 2.51 | 0.10 | < 0.02 | 102.91 |
103 | 2199.3 | 170.42 | 34.718 | 34.03 | 2.17 | 2.50 | 0.06 | < 0.02 | 110.54 |
1060 | 2418.6 | 172.95 | 34.723 | 34.05 | 2.06 | 2.48 | 0.05 | < 0.02 | 113.45 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
Oxygen-CTD 21-SBE 43-SN 2125 | Seabird | SBE 43 | 2125 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) |
Temperature CTD 21 - SN 5422 | Seabird | SBE3plus | 5422 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |