Please login if you have access to particular applications.
Deployment Details
Survey: - SS2013_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 9
Operation No.: 9
Gear: CTD 21,Conductivity CTD 21 - SN 3309,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70371,Oxygen-CTD 21-SBE 43-SN 2125,Pressure CTD 21,Temperature CTD 21 - SN 5422,Transmissometer - CTD 22 -CST-1421DR
When: 2013-07-05 05:15 to 2013-07-05 06:57 UTC
Where:
32° 34.2' S
114° 22.2' E
to
32° 34.4' S
114° 22.0' E
Maximum Depth (m): 1894.7
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1024 | 6.6 | 228.69 | 33.413 | < 0.02 | 20.27 | 0.04 | 0.03 | 0.04 | 2.13 |
1006 | 19.9 | 0.04 | 19.93 | 0.05 | 0.03 | 0.13 | 2.16 | ||
1059 | 47.5 | 231.07 | 33.580 | < 0.02 | 19.65 | 0.04 | 0.03 | 0.09 | 2.13 |
1055 | 100.8 | 0.98 | 19.25 | 0.12 | 0.03 | 0.11 | 2.41 | ||
1063 | 118.2 | 226.18 | 33.791 | 0.52 | 18.97 | 0.07 | 0.02 | < 0.02 | 2.11 |
1071 | 141.7 | 0.43 | 18.82 | 0.06 | 0.03 | < 0.02 | 2.02 | ||
1010 | 175.8 | 0.49 | 18.41 | 0.08 | 0.04 | < 0.02 | 1.93 | ||
1054 | 198.8 | 228.96 | 33.716 | 0.97 | 17.65 | 0.13 | 0.04 | 0.06 | 1.78 |
1058 | 299.4 | 236.70 | 33.404 | 4.20 | 14.28 | 0.38 | 0.10 | 0.15 | 1.61 |
1061 | 500 | 247.02 | 34.720 | 15.77 | 9.73 | 1.13 | 0.03 | 0.15 | 4.24 |
1050 | 600.9 | 225.93 | 34.546 | 22.15 | 8.10 | 1.54 | 0.02 | 0.10 | 9.99 |
1001 | 700.6 | 202.38 | 34.417 | 28.74 | 5.98 | 2.02 | 0.02 | 0.03 | 25.10 |
1068 | 998.2 | 177.18 | 34.444 | 34.15 | 3.63 | 2.47 | < 0.02 | < 0.02 | 58.86 |
1067 | 1298.2 | 152.28 | 34.564 | 35.35 | 3.30 | 2.59 | < 0.02 | < 0.02 | 81.08 |
103 | 1599 | 158.26 | 34.635 | 34.84 | 2.81 | 2.54 | 0.03 | < 0.02 | 89.64 |
1060 | 1894.7 | 164.33 | 34.690 | 34.29 | 2.47 | 2.49 | 0.05 | < 0.02 | 99.39 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21 - SN 3309 | Seabird | SBE4C | 3309 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70371 | QCP | 2300HP | 70371 | PAR (uE/m**2/sec) |
Oxygen-CTD 21-SBE 43-SN 2125 | Seabird | SBE 43 | 2125 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) |
Temperature CTD 21 - SN 5422 | Seabird | SBE3plus | 5422 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |