Deployment Details
Survey: - SS2012_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 23
Operation No.: 23
Gear: CTD 21,Conductivity CTD 21-SN 2312,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70111,Oxygen CTD 21-SBE 43-SN 1794,Pressure CTD 21,Temperature CTD 21 - SN 4718,Transmissometer - CTD 22 -CST-1421DR
When: 2012-08-31 05:59 to 2012-08-31 07:45 UTC
Where:
27° 29.9' S
105° 00.1' E
to
27° 30.7' S
105° 01.5' E
Maximum Depth (m): 1998.9
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
19 | 10.3 | 228.42 | 35.193 | < 0.02 | 21.07 | 0.03 | 0.05 | 3.01 |
18 | 25.8 | < 0.02 | 21.04 | 0.04 | < 0.02 | 3.02 | ||
17 | 43.8 | < 0.02 | 20.74 | 0.05 | < 0.02 | 3.06 | ||
16 | 65.5 | 223.27 | 35.531 | 0.35 | 20.23 | 0.07 | < 0.02 | 3.01 |
15 | 101.9 | < 0.02 | 19.96 | 0.04 | < 0.02 | 2.57 | ||
14 | 153.3 | 1.13 | 18.94 | 0.18 | 0.03 | 2.36 | ||
13 | 201.2 | 220.07 | 35.820 | 0.29 | 18.01 | 0.09 | 0.06 | 2.42 |
12 | 350.5 | 6.83 | 12.89 | 0.57 | < 0.02 | 2.27 | ||
11 | 400.5 | 243.08 | 34.967 | 10.18 | 11.36 | 0.77 | < 0.02 | 2.83 |
10 | 504.8 | 246.50 | 34.706 | 15.43 | 9.55 | 1.09 | < 0.02 | 4.47 |
9 | 602.2 | 240.28 | 34.633 | 17.93 | 8.98 | 1.24 | < 0.02 | 5.94 |
8 | 781.9 | 185.70 | 34.453 | 29.37 | 5.99 | 2.02 | < 0.02 | 31.44 |
7 | 901.4 | 33.83 | 5.19 | 2.40 | < 0.02 | 58.39 | ||
6 | 1005.1 | 150.76 | 34.43 | 4.51 | 2.44 | < 0.02 | 62.68 | |
5 | 1202.4 | 142.55 | 34.550 | 35.44 | 3.80 | 2.53 | < 0.02 | 77.92 |
4 | 1402.9 | 35.50 | 3.35 | 2.52 | < 0.02 | 88.09 | ||
3 | 1602.6 | 147.22 | 34.652 | 35.14 | 3.00 | 2.50 | 0.04 | 95.16 |
2 | 1803.1 | 153.54 | 34.685 | 34.71 | 2.68 | 2.48 | < 0.02 | 101.71 |
1 | 1998.9 | 160.83 | 34.706 | 34.25 | 2.43 | 2.42 | 0.02 | 105.84 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21-SN 2312 | Seabird | SBE-4 | 2312 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 21-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 101526 | Pressure (decibars) |
Temperature CTD 21 - SN 4718 | Seabird | SBE3plus | 4718 | Temperature (deg C) |
Transmissometer - CTD 22 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |