Please login if you have access to particular applications.
Deployment Details
Survey: - SS2011_V02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 28
Operation No.: 28
Gear: CTD 21,Conductivity CTD 21-SN 3169,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70111,Oxygen CTD 21-SBE 43-SN 1794,Pressure CTD 21,Temperature CTD 21 - SN 4718,Transmissometer - CTD 21 -CST-1016DR
When: 2011-05-26 05:03 to 2011-05-26 05:44 UTC
Where: 30° 36.0' S 177° 00.0' E
Maximum Depth (m): 1500.6
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|
18 | 10.4 | < 0.02 | 21.30 | 0.04 | 0.86 | ||
16 | 15.1 | < 0.02 | 21.30 | 0.04 | 0.85 | ||
15 | 29.1 | 0.02 | 21.31 | 0.04 | 0.82 | ||
13 | 50.5 | 227.86 | 35.653 | 0.02 | 20.84 | 0.05 | 0.86 |
11 | 75.7 | < 0.02 | 20.51 | 0.08 | 0.94 | ||
9 | 99.1 | 2.04 | 19.37 | 0.23 | 1.33 | ||
8 | 149.5 | 4.64 | 17.49 | 0.39 | 1.76 | ||
7 | 201.9 | 5.69 | 16.65 | 0.44 | 2.00 | ||
6 | 299.4 | 9.82 | 14.38 | 0.73 | 3.53 | ||
5 | 501 | 17.36 | 10.78 | 1.19 | 7.48 | ||
4 | 748.7 | 24.75 | 7.34 | 1.68 | 13.81 | ||
3 | 749.5 | 24.61 | 7.33 | 1.69 | 13.81 | ||
2 | 999.7 | 204.09 | 34.380 | 30.45 | 5.31 | 2.09 | 29.54 |
1 | 1500.6 | 35.36 | 3.04 | 2.50 | 90.93 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21-SN 3169 | Seabird | SBE4C | 3169 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 21-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 101526 | Pressure (decibars) |
Temperature CTD 21 - SN 4718 | Seabird | SBE3plus | 4718 | Temperature (deg C) |
Transmissometer - CTD 21 -CST-1016DR | Wetlabs | C-Star | CST-1016DR | Transmittance (%) |