Please login if you have access to particular applications.
Deployment Details
Survey: - SS2011_V02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 19
Operation No.: 19
Gear: CTD 21,Conductivity CTD 21-SN 3169,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70111,Oxygen CTD 21-SBE 43-SN 1794,Pressure CTD 21,Temperature CTD 21 - SN 4718,Transmissometer - CTD 21 -CST-1016DR
When: 2011-05-22 09:08 to 2011-05-22 09:43 UTC
Where: 30° 00.0' S 169° 00.0' E
Maximum Depth (m): 1501.8
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|
17 | 9.7 | 0.05 | 21.31 | 0.06 | 0.86 | ||
15 | 15 | 0.09 | 21.32 | 0.07 | 0.85 | ||
13 | 30.1 | 0.07 | 21.33 | 0.07 | 0.83 | ||
11 | 49.9 | 224.43 | 35.656 | 0.06 | 21.33 | 0.07 | 0.84 |
9 | 75.3 | 0.04 | 21.33 | 0.06 | 0.84 | ||
8 | 99.6 | 0.66 | 21.15 | 0.12 | 0.91 | ||
7 | 150.1 | 4.50 | 18.77 | 0.36 | 1.60 | ||
6 | 201 | 5.45 | 17.45 | 0.43 | 1.86 | ||
5 | 300 | 10.01 | 14.52 | 0.73 | 3.60 | ||
4 | 501.2 | 17.97 | 10.70 | 1.23 | 8.11 | ||
3 | 750.2 | 25.06 | 7.46 | 1.72 | 18.26 | ||
2 | 999.2 | 195.34 | 34.468 | 29.56 | 5.75 | 2.05 | 35.01 |
1 | 1501.8 | 34.62 | 3.33 | 2.45 | 85.18 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21-SN 3169 | Seabird | SBE4C | 3169 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 21-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 101526 | Pressure (decibars) |
Temperature CTD 21 - SN 4718 | Seabird | SBE3plus | 4718 | Temperature (deg C) |
Transmissometer - CTD 21 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |